IIWAV"'B
<br />CORE LABORATORIES
<br />Q U A L I T Y A S S U R A N C E M E T H O D S
<br />R E F E R E N C E S A N D N O T E S
<br />Report Date: 11/23/97
<br />Core Laboratories - Gulf States - Houston, T% • HE
<br />Core Labora[ori es - Houston, T% • HP
<br />Core Laboratories - Indianapolis, IN • IN
<br />Core Laboratories - Lake Charles, LA • LL
<br />Core Laboratories - Long Beach, CA • LB
<br />Lore Laboratories - Tampa, FL • TP
<br />Lore Laboratories - Valparaiso, IN • VP
<br />Othe r Subcontract Laboratories • XX
<br />EXPLANATION OF DATA OUALI FIERS - ORGANIC PARAMETERS
<br />U - This qualifier indicates that the analyte was analyzed
<br />for but not detected.
<br />J - This qualifier indicates that the value is an estimate.
<br />It is used when a compound is determined to be present
<br />based on the mass spectral data but at a concentration
<br />less than the practical quantitation limit of the
<br />method.
<br />E - This qualifier indicates that a sample result is an
<br />estimate because the concentration exceeded the upper
<br />calibration range of the instrument.
<br />EXPLANATION OF DATA DUALI FIERS - METALS 8 INORGANIC PARAMETERS
<br />U - This qualifier indicates [ha[ [he analyte uas analyzed
<br />for but no[ detected.
<br />B - This qualifier indicates that [he analyte was detected
<br />at a level below the reporting limit but greater than
<br />or equal to the instrument detection limit.
<br />EXPLANATION OF DATA FLAGS - ALL PARAMETERS
<br />B - This flag indicates that an analyte is present in
<br />the method blank as well as in the sample. The client
<br />should consider this when evaluating the data.
<br />E - This flag indicates the reported value is estimated due
<br />to sample matrix interference.
<br />N - This flag indicates that a post digestion spike for
<br />GFAA analysis is outside quality control limits.
<br />X - This flag irxli cat es that a surrogate recovery is
<br />outside quality control limits.
<br />Y - This flag indicates a spike or spike duplicate recovery
<br />is outside quality control limits.
<br />Z - This flag indicates a relative percent difference for
<br />a spike and spike duplicate is outside quality
<br />control limits.
<br />• - This flag indicates a relative percent difference for
<br />a duplicate analysis is outside quality control
<br />limits.
<br />- This flag indicates a percent recovery for a standard
<br />is outside quality control limits.