0 <br />Opening ID <br />Type of Feature <br />Excavated Dimension <br />Eroded Dimension <br />Present Dimension <br />Depth <br />Shape of Opening <br />Surficial Material <br />Depth to Bedrock <br />Drainage <br />Existing Access Deterrents <br />Preferred Closure Method <br />361 <br />Adit <br />6.00 X 9.00 Ft <br />6.00 X 9.00 Ft <br />5.00 X 7.00 Ft <br />Over 1000 feet <br />Trapezoidal <br />Soil /colluvium <br />8 feet <br />Standing water /floor <br />Signs <br />Culvert And Grate <br />is <br />Install a minimum of 20 linear feet of 36 -inch diameter culvert according to <br />Corrugated Steel Adit Closure specifications. The culvert shall have a locking <br />grated access door. <br />Opening ID <br />Type of Feature <br />Excavated Dimension <br />Eroded Dimension <br />Present Dimension <br />Depth <br />Shape of Opening <br />Surficial Material <br />Depth to Bedrock <br />Drainage <br />Existing Access Deterrents <br />Preferred Closure Method <br />362 <br />Adit <br />6.00 X 7.00 Ft <br />6.00 X 7.00 Ft <br />2.50 X 3.00 Ft <br />878 feet <br />Arch <br />Colluvium /rock <br />4 feet <br />None <br />None <br />Grate W /access <br />Install 42 square feet of grating according to the Steel Grated Adit Closure <br />specifications. A 4 -inch square hole shall be cut in one bottom corner of the <br />grate, and a framed 2'x 4" slot shall be constructed in the top center of the <br />grate. <br />8 <br />