Laserfiche WebLink
<br />(1) Measure monthly water conductivity, PH, temperature, flow/depth for surface water <br />monitoring stations (SW's) <br />(2) Measure weekly forconductivity, PH, temperature, oil/grease, settleable solids, and flowfor <br />ail discharging water from Outfalls 007, 008 and 009. Test for total suspended solids, <br />settleable solids,and iron once a month for Outfalls 007, 008 and 009. <br />(3) Full suite laboratory analysis (February, May, August, and November on quarterly <br />schedule), if pond(s) are discharging for Outtalls 007 008 and 009. <br />(4) Measure water conductivity, PH, temperature, oiUgrease, and flow/depth. Have full suite <br />laboratory analysis February and August for Semi-Annual schedule and August for Annual <br />schedule) for listed groundwater monitoring wells and surface monitoring stations. <br />(5) Measure monthly water depth for groundwater monitoring wells (GW's). <br />(li) Measure water conductivity, PH, temperature, and depth. Have full suite laboratory <br />analysis using the Ground Water Parameters on folbwing list (February, May, August, and <br />November) <br /> <br />r ~ <br />(REVISED 18 Aug 2003) 2.04.7-40 <br />