Laserfiche WebLink
• 2002 Annual Hydrologic Report Page 5 <br />Piezometers CRDA-01 thru 06 at the Cameo Refuse Disposal Areas (CRDA) No. 1 and <br />No.2 continued to be monitored quarterly. Data page GC-11 includes measurements <br />for this Year. A graphical representation of the water level elevations in CRDA-01 is <br />shown on Diagram G02-4. Water levels decreased during Year. Most of the original <br />CRDA-# piezometers and the PZ-# piezometers showed only slight variation during the <br />Year. <br />The results of water level measurements at the unit train loadout this Year are listed on <br />Data page GB-2. Diagrams G02-5 and 6 are graphical representations of water level <br />elevations in these piezometers. Table G02-2 was prepared to show statistics on these <br />water levels corresponding to high and low flows in the adjacent river. Quality <br />information is presented on page GD-13. <br />A former mine dewatering hole (N-1) located at the North Decline area of the mine is <br />used to monitor the water level in the abandoned portions of the Roadside South Portal. <br />The water level must be maintained between elevation 4755 and 4762 to assure the <br />siphon continues to function. This 7-foot elevation range equates to about 2.3 million <br />• gallons per foot or about 16.1 million gallons (ref. Table M02-1 ). The discharge from <br />the siphon is increased or decreased, by adjusting a valve, depending on water level <br />measurements in well N-1. Changes in the elevation of the Northwest Intake Pool are <br />gradual because each foot of increase or decrease represents 2.3 million gallons. <br />Since discharge point 016 was put into service, the water level in N-1 is virtually <br />constant and it is expected to stay within the range of 4757.7 to 4758.0. The results of <br />monitoring N-1 are presented in Table M02-2. <br />In order to characterize the Rollins Sandstone two surface and two underground wells <br />were installed during June 1997. The surface wells were installed at the north decline <br />and the unit train loadout. The underground wells were installed in the North and South <br />Portals. Depth to water ranged from 56.5 feet below grade in the North Decline well to <br />artesian in the North Portal well. Monitoring of these wells will continue in accordance <br />with permit requirements. Rollins-1 and 4 located underground in the North and South <br />Portals respectively have been sealed. Depth to water data is presented on data page <br />GE-1. Quality information is presented on pages GE-10 and GE-11. <br /> <br />