Laserfiche WebLink
Mechanical Integrity Test <br />Casing or Annulus Pressure Test for Well C03858-04556 <br />U. S. Envimomental Protection Agency <br />Underground Injection Control Program, UIC Implementation Section, 8WM-0W <br />999 18th Street, Suite 500, Denver, CO 80202-2466 <br />EPA Witness: None Date: 9/20/2006 <br />Test conducted by: Adler Hot Oil Service Inc. <br />Others present: Ed Coolev. Ken Steele. Paul J. <br />Well name: 20-19 Type: ER swD NancolRe Status: AC TA UC <br />Field: Central Piceance Creek Basin <br />Location: 464' N & 553' W F/ SE Comer Sec 20 T1 S, R97W 6th P.M. County: Rio Blanco State: Go. <br />Operator: American Soda, L_ L. P., 2717 County Road 215, Parachute, CO 81635 <br />Last MIT: 8/25/04 <br />Max Allowed Pressure si 1000 Max R rted Press i <br />is this a regularly scheduled test? [ X ]Yes [ ] No <br />Initial test for permit? [ ]Yes ( ] No <br />Test after well rework [ ]Yes [ j No <br />Well injecting during test? [ ]Yes [ X ] No 0 GPM <br />CASING/TUBING ANNULI <br />7" Short String 7" Long String <br />Time: Minutes Casin Casin Tubin <br />Start Test 358 psig 410 psig N/A psi <br />5 355 400 N/A <br />10 353 400 N/A <br />15 352 400 N/A <br />20 351 400 N/A <br />25 350 400 WA <br />30 350 400 N/A <br />Result circle Pas Fail Pass Fail Pass Fail <br />jX]No <br />Flc <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />Initial casing/tubing annulus pressure 0 psig <br />Does the annulus pressure build back up? [ J Yes <br />