Laserfiche WebLink
December 23, / 999 <br />PcrKe 6-3 <br />• - Record the exact measurement as read from [he cable and/or [ape. Do not perform any <br />calculations or rounding before recording value. If corrections are necessary, due to <br />adjustments (splices) in the sounder cable, perform those calculations AFTER the raw <br />data has been recorded. <br />- After recording the depth, repeat the measurement to confirm the depth. <br />- Turn the meter off and reel up cable. <br />- Decontaminate probe and cable according to the Standard Operating Procedures for <br />Equipment Decontamination, if applicable. <br />- Replace inner and outer protective caps. Be sure to lock outer cover, if applicable, <br />replacing old lock if necessary. ,Alternatively, proceed with groundwater sampling. <br />Personnel will also follow these additional guidelines for water level sounding: <br />- Do not drop anything down the well. If any equipment is lost down the well, document <br />the occurrence. <br />- Report any damaged, blocked, or otherwise deficient wel is to the environmental manager <br />• for repair or closure. <br />u <br />Agapito Associates, Inc. <br />