Laserfiche WebLink
PARTI <br />Page No. 9 <br />Permit No.: CO-0044776 <br />• d. Influent Monitorine <br />Influent Parameter ~ Frequencv ~ ~ ~ ~ -Sample Tvoe <br />Flow, MGD Continuous Recorder <br />BODs, mg/1 Monthly Composite <br />TSS, mgll Monthly Composite <br />Self-monitoring sampling by the permittee for compliance with the monitoring requirements specified above shall be <br />performed prior to entering Pond B for Outfa11004. <br />If the permittee, using the approved analytical methods, monitors any pazame[er more frequently than required by this <br />permit, [hen the results of such monitoring shall be included in the calculation and reporting of the values required in the <br />Dischazge Monitoring Report Form (DMRs) or other forms as required by the Division. Such increased frequency shall <br />also be indicated. <br />e. Oil and Grease Monitorine <br />For every outfall with oil and grease monitoring, in the event an oil sheen or floating oil is observed, a grab sample shall <br />be collected, analyzed, and reported on [he appropriate DMR. In addition, corrective action shall be taken immediately <br />to mitigate the discharge of oil and grease. A description of the corrective action taken should be included with the <br />DMR. <br />2. Salinity Parameters <br />In order [o obtain an indication of the quantity of Salinity, measured as total dissolved solids (TDS), being discharged from <br />the site the permittee shall monitor the wastewater effluent at the following frequencies: <br />Outfall Frequencv Samole Tvoe <br />001, 002, 003, 004, 005, 006, 007, 008 Quarterly Grab <br />Self-monitoring samples taken in compliance with the monitoring requirements specified above shall be taken at those <br />locations listed in Part I.B.1. <br />Where, based on a minunum of 5 samples, the pemuttee demonstrates to the satisfaction of the Division that the level of total <br />dissolved solids (TDS) in the effluent can be calculated based upon the level of electrical conductivity, the pemtittee may <br />measure and report TDS in terms of electrical conductivity. <br />3. Special Monitorine <br />a. Twelve Time Analysis - Outfall 006 <br />In order to determine the quality of water dischazged at this facility, the pernvttee is required to perform a twelve time <br />analysis for the following parameters at outfall 006. The fast sampling shall occur during the first month after the permit <br />becomes effective, or when discharge commences, and sampling shall continue for the next eleven consecutive months. <br />If no discharge occurs during [he month, sampling shall resume when discharge resumes and continue until twelve <br />samples have been collected and analyzed using approved methods with method detection limits as low or lower than <br />those specified in Part I.E.3. of the permit. <br />A summary report in the form of a letter shall be submitted to the Permits Unit by October 31, 2005. This report shall <br />include all individual sample results collected over the twelve month period. If sampling is incomplete because no <br />discharge occurred during part or all of the period, this shall be noted in the report. If sampling has not yet been <br />completed by this date, this twelve time analysis requirement shall continue until twelve samples have been collected and <br />analyzed and the results have been submitted to the Permits Unit. <br />~e Part I.C. for Definitions. <br />