Laserfiche WebLink
cases, this effect can only be eliminated by reducing the "c" value. <br />************************************************************************ <br />USER SELECTED option to maintain strength greater than zero <br /> <br />** Factor of safety calculation for surface # 196 ** <br />** failed to converge within FIFTY iterations ** <br />** ** <br />** The last calculated value of the FOS was -58.3052 ** <br />* * This will be ignored for final summary of results <br />*************************************ss********************** <br />Circular surface (FOS=-58.3052) is defined by: xcenter = 50.70 <br />ycenter = 991.99 Init. Pt. = 78.29 Seg. Length = 8.00 <br />************************************************************* <br />** Factor of safety calculation for surface # 197 ** <br />** failed to converge within FIFTY iterations ** <br />** ** <br />** The last calculated value of the FOS was -50.8346 ** <br />** This will be ignored for final summary ofresults ** <br />************************************************************* <br />Circular surface (FOS=-50.8346) is defined by: xcenter = 49.32 <br />ycenter = 1023.27 Init. Pt. = 78.29 Seg. Length = 8.00 <br />************************************************************* <br />** Factor of safety calculation for surface # 198 ** <br />** . failed to converge within FIFTY iterations ** <br />** ** <br />** The last calculated value of the FOS was-132.5097 ** <br />** This will be ignored for final summary of results ** <br />*********s*************************************************** <br />