My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PERMFILE131458
DRMS
>
Back File Migration
>
Permit File
>
400000
>
PERMFILE131458
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 10:32:17 PM
Creation date
11/25/2007 11:13:49 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1982057A
IBM Index Class Name
Permit File
Doc Date
5/1/2003
Section_Exhibit Name
Tab 15 Hydrologic Monitoring Program
Media Type
D
Archive
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
results. Devices used to sample alluvial wells include either bailers or submersible pumps, and <br />either bailers, submersible pumps, or positive displacement pumps are used to sample bedrock <br />wells. <br />Historic Ground Water Monitoring Program. The Historic Ground Water Monitoring Program is <br />described in Appendix 15-1. In the summer of 1979, Peabody Coal Company initiated a ground <br />water baseline monitoring study of the Seneca II-W Mine. At that time, the proposed permit area <br />extended approximately one and one-half miles south of the southern border of the 1990 permit <br />area. Initial baseline monitoring incorporated this larger area as evident from the locations of the <br />monitoring sites. Wells at Sites 1 through 9 were constructed during the summer of 1979. <br />Wells 10W through 13W were completed during the fall of 1981 to provide additional baseline <br />ground water level data. A site summary of ground water monitoring wells at Seneca II-W is <br />presented in Table 15-2. Historical information for ground water wells is contained in Table 15- <br />3. <br />Pre-October, 1991 Ground Water Monitoring Program. The Pre-October, 1991 Ground Water <br />Monitoring Program is found in Appendix 15-2. The schedule of water level measurements <br />depended upon when mining was to begin. Since mining began in the summer of 1990, all <br />overburden and coal wells listed in Appendix 15-2 were monitored once very two months, <br />except for the December/January period. This schedule reflected the frequency of water level <br />measurements followed at Peabody's Seneca II Mine. Alluvia! wells were monitored monthly <br />except for December through March. <br />As a result of the failure of several of the wells drilled in 1979 (AHR, February 28, 19871, <br />Peabody drilled an additional 12 wells in 1987. These wells were 140V to 19A. Four new <br />alluvial wells IGW-S2W-20A to 23A1 were installed by Peabody in the summer of 1990 in areas <br />of proposed NPDES ponds to provide baseline water level and quality data on a semiannual <br />basis. A production well (GW-S2W-201TC) and a water level observation well (GW-S2W- <br />200TC) was completed in the Trout Creek Sandstone aquifer in order to supply water for <br />domestic and industrial needs at the mine. Locations of the 18 wells are found in Exhibit 7-1 <br />and well descriptions are found in Appendix 7-1. <br />1991 Ground Water Monitoring Program. The 1991 Ground Water Monitoring Program is <br />described in Appendix 15-3. Upon approval of PR1 in October, 1991, Peabody incorporated the <br />monitoring program detailed in Appendix 15-3. This revision basically addressed the <br />12 Revised 11/15/95 <br />
The URL can be used to link to this page
Your browser does not support the video tag.