My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PERMFILE131137
DRMS
>
Back File Migration
>
Permit File
>
400000
>
PERMFILE131137
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 10:31:59 PM
Creation date
11/25/2007 10:57:14 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1980005
IBM Index Class Name
Permit File
Doc Date
12/11/2001
Doc Name
LABORATORY PROCEDURES
Section_Exhibit Name
TAB 06 APPENDIX 6-2
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />Determination of Total Sulfur - Continued <br />4. Turn on oxygen; set pressure at 15 psi, flow rate <br />to 0.5 liter/min. <br />5. Fill iodate buret. <br />6. Fill titrating chamber to just above oxygen inlet <br />port on side of chamber and add one measure of starch <br />solution. <br />7. Adjust to proper endpoint with endpoint controls <br />(refill iodate buret after endpoint adjustment). <br />8. Place sample crucible on pedestal, making sure it is <br />centered; carefully raise sample into uppermost <br />position and close switching lever. Make certain <br />sample platform seals when closed. <br />9. Push red button on timer to start analysis. <br />• <br />10. Plate current must reach 350-400 ma for at least 15 <br />seconds during the analysis; if not, rerun sample. <br />11. If buret is still changing when timer approaches zero <br />position or combustion has not taken place, set timer <br />switch to off position, which keeps furnace operating, <br />and maintain in this position until buret reading <br />is stable for 2 minutes. <br />12. Lower sample platform and remove crucible with tongs. <br />13. Refill iodate buret. <br />14. Return to step 6 and proceed. (Drain titration vessel <br />after every third sample, refill and adjust endpoint). <br />15. After shutdown, drain titration vessel, rinse with <br />water, refill with weak ammonium hydroxide solution, and <br />let air flow bubble through for several minutes (removes <br />precipatate buildup from titration vessel). Drain and <br />flush with water several times. Refill with water <br />until next group of samples are analyzed. <br />• <br />Refer to Leco instruction manual for any deviation to the above <br />instructions and any maintenance of the furnance or titration <br />apparatus. <br />6-58 <br />
The URL can be used to link to this page
Your browser does not support the video tag.