Laserfiche WebLink
Exhibit 60C <br />Subsidence Evaluation and 2004 Geologic Hazard Field Observations <br />West Flatiron Lease Area <br />• <br />TABLE 1 <br />Maximum Subsidence Parameters For <br />West Flatiron Lease Area t'i <br /> <br />Parameter Panel 18A (t=12ft) Panels 18-19 (to12 it) tsl Panels 20-21 (to12ft) <br />W /d: Max <br />Min 18A 690/600 = 1.15 <br />690/1310 0.53 18 970 / 750 = <br />970 /1700 = 1.29 <br />0.58 20 970 / 1030 <br />970 / 2250 = 0.94 <br />0.43 <br />Max <br />Min 19 970 / 910 <br />970 / 2250 1.07 <br />0.43 21 970 / 1300 <br />970 / 2175 = 0.75 <br />0.45 <br />S°o=a~•tt4l <br />(a°o=S~dt) 1.7 to3.8ft <br />(0.14 to 0.32) 2.2 to6.5ft <br />(0.18 to 0.54) 2.9 to6.5ft <br />(0.24 to 0.54) <br />Sm=e•ttsl <br />(a = S„~t) 6.0 to 9.6 <br />(0.5 to 0.8) 4.S t09.6ft <br />(0.4 to 0.8) 4.8 t09.Oft <br />(0.4 to 0.75) <br />Sm/d lel (0.005 to 0.016) (0.0021 to 0.013) (0.0021 to 0.009) <br />Mm (2.2 to 3.0 S„Jd) n1 0.011 t0 0.048 0.005 t0 0.039 0.005 l0 0.027 <br />Em (in terms of S„Jd) Isl <br />(1.3 to 1.5 S„Jd) 0.006 to 0.024 0.003 to 0.020 0.003 to 0.014 <br />-Em (in terms of Sm/d) Isl -0.006 to -0.038 -0.003 to -0.031 -0.003 to -0.022 <br />Maximum Crack 1 5- 15 ft 5- 20 ft 5- 15 ft <br />Deptht9t 2 10-20ft 10-35ft 10-20ft <br />Break Angle 1101 0 - 5° 0 - 5° 0 - 5° <br />Angle of Draw tf0~ 10 - 20° 10.20° 10 - 20° <br />~'~ Maximum subsidence parameters include the total length of mining panels 18-21, and therefore include the Box <br />Canyon mining area as well as the West Flatiron Lease area; t is the average coal extraction thickness (12 ft), which <br />may be more or less than this average. <br />tzl Maximum vertical displacement, tilt, and horizontal strain apply to ground surfaces with slopes less that 30%; <br />values may be higher on slopes greater that 30 percent. <br />13lAll longwall panels are numbered according to their planned panel identification. <br />I`t Subsidence and subsidence factor above gate road (chain) pillars. <br />fs1 Maximum vertical displacement (subsidence) range above the longwall panel centers, based on the average <br />planned coal extraction thickness of 12 feet, is obtained from Figure 4, Exhibit 60B. <br />tel Ratio of the range of maximum vertical displacement to overburden depth range for the five projected longwall <br />panels. Minimum overburden tlepth to the B seam is located in the Raven Gulch tributary in the West Flatiron lease <br />area above the projected centerlines of longwall panels 18 through 21. Minimum overburden depth of the projected <br />centerline of longwall panel 18A (600 feet) is located 300 feet west of the east West Flatiron Lease boundary. <br />nl Maximum range of tilt values, in terms of Sm/d, is obtained from Figure 1. <br />Isl Maximum range of positive and negative horizontal strain in terms of Sm/d is obtained from Figure 1. <br />191 Maximum crack depth (in feet) in bedrock that is estimated to locally occur near cliffs, ledges, or steep slopes on <br />either side of West Flatiron. The first depth range (1) is for bedrock sloping less than or equal to 30 percent. The <br />second depth range (2) is for steep bedrock sloping more than 30 percent and cliffs. No cracks are predicted to <br />occur in alluvium. No cracks are predicted to occur at the surface of colluvium thicker than about 10 feet <br />• t10~ Predicted range of break angle and angle of draw, measured from a vertical reference. <br />831-032.650 Wright Water Engineers, Inc. Page 11 <br />November 2004 <br />