Laserfiche WebLink
<br />The following fire fighting plan will be followed when evidence <br />of combustion is detected in the refuse pile: <br />1. Material will be removed from the area where <br />combustion is taking place using front-end <br />loaders, dozers, backhoes, trucks and/or <br />other suitable equipment. <br />2. The removed material will be placed at an <br />- alternate location within the ref use disposal <br />area and spread, rolled, and wet, if <br />necessary u.-.til it is cooled sufficiently. <br />3. The material will then be compacted with a <br />loader or sheepsfoot compactor. If <br />necessary, a layer of non-combustable <br />material will be placed over the susceptible <br />area to cut off oxygen and prevent <br />reoccurance of combustion. <br />4. The area where material was removed from will <br />be regraded and recompacted. New material <br />will be placed in the void if the amount of <br />material removed was large. If necessary, <br />non-combustable material will be placed over <br />the susceptible area to cut off oxygen and <br />prevent reoccurance of combustion. <br />Only those persons authorized by the operator, who have an <br />understanding of this plan, shall be involved in fire fighting <br />in the refuse area. ' <br /> <br /> <br />