Laserfiche WebLink
NORTHWEST COLORADO CONSULTANTS, INC. <br />Project: Haul Road Y-8 <br />Location: Hayden, Colorado <br />Client: Seneca Coal Company <br />Project No.: 95-2384 <br />Repot No.: 63 <br />Date: 7/16/96 <br />Time: 1.5 <br />Mileage: 50 <br />EngrJTech: CR <br />~J <br />Work Performed: <br />As requested, we visited the project site on this date and conducted nuclear density test No.'s 122 and 123 on the <br />fill section at Sta. 30+00 to Sta. 35+00. <br />Remarks: <br />The material tested generally met project specifications for compaction, however, was in excess of 6% below <br />optimum for moisture content. Chuck McCulloh, from Seneca Coal, stated that he was aware of this situation and <br />that a water truck was unavailable at the present time. <br />Please refer to that attached sheet for results of today's testing. <br />u <br /> <br />