Laserfiche WebLink
,. <br />~~ <br />A-2 .8 GE-1 TEST <br /> <br />Aquifer-test data for well GE-1 is presented in Table A-11. Recovery data was <br />collected after the well was airlifted on September 18, 1985. The recovery data <br />shown on Figure A-13 gives a transmissivity value of 22 gal/day/ft for the QR <br />aquifer near well GE-1. The recovery of drawdown data prior to a t/t' of one <br />indicates a recharge source to QR aquifer in this area. Permeability of the QR <br />aquifer near well GE-1 is 0.03 ft/day using the transmissivity of 22 gal/day/ft. <br />A-2.9 GE-3 TEST <br />A single well recovery test on well GE-3 was conducted on September 18, 1985. <br /> <br />Recovery data was collected after the well was airlifted and bailed. Aquifer-test <br />data for well GE-3 is presented in Table A-12. <br />The plot of the recovery data is shown on Figure A-14. A straight line fit of <br />data leading to complete recovery yields a transmissivity value of 13 gal/day/ft. <br />This value is thought to be indicative of the transmissivity for the Second White <br />Sandstone aquifer near well GE-3. Permeability was calculated to be 0.01 ft/day. <br />A-2.10 GF-1 TEST <br />A constant head flow test was conducted on well GF-1 on September 9, 1986 <br />~~ <br />The discharge rate of well GF-1 was monitored during the 250 minute flow test. A <br />pressure reading was taken to establish a static water level for the 20 mile <br />sandstone near well GF-1. Table A-13 presents the aquifer-test data collected <br />during the flow test on well GF-1. <br />A-~ REVISED FEB 13 '87 <br />