Laserfiche WebLink
Calculations <br />2-Year, 24-Hour Precipitation Event = 1.1" <br />Inches of Runoff @ CN = 87 = 0.28" <br />CN = 87 0.12" <br />CN = 75 = .OS" <br />(Source - Procedures Eor Determining Peak Flows in Colorado, pp 52, 57, 64; <br />attached Eor reference). <br />CFS/in of runoff - from Figure II-2, Peak Rates of Dischjarge for Sma11 <br />Watzrsheds, Procedures for Determining Peak Flows in Colorado, p17; attached <br />for reference. <br />Peak Flow = (CFS/in)(inches of runufE)(Slope Adjustment factor) <br />Slope = 14Z. <br />Slope ad.lustment factor .98 where area < 50 acres. <br />.97 where 50 < area < 100. <br />.96 where area > 100 acres. <br />(Source - Table II-6, Slope adjustment factors by drainage areas, Procedures <br />for Determining Peak Flows in Colorado; attached for reference). <br />Flow Depth (D) _ (Qn/KS1/2).375 where Q = peak flow. <br />n = roughness coefficient = .035. <br />~ K = discharge factor = 14.8 Eor D/b = <br />• .1, sideslopes at 1:1. <br />Ditch-Bottom Width (B) = D x 10. <br />2/3 1/2 <br />Velocity (V) = 1.49/n R S__ whe.r.e,n roughness....___._ _. .. . <br />_ __ coefficient _ .035. <br />R = hydraulic radius. <br />5 = ditch gradient (ft/ft). <br /> <br />REVISED FE8 13 '87 <br />