My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PERMFILE126866
DRMS
>
Back File Migration
>
Permit File
>
300000
>
PERMFILE126866
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 10:24:01 PM
Creation date
11/25/2007 3:59:35 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2004026
IBM Index Class Name
Permit File
Doc Date
7/4/2004
Doc Name
First Adequacy Review Reply
From
LJ Development Inc
To
DMG
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL REQUIREMENTS FOR BURIED LINE CROSSINGS CONT. <br />E. ^ All buried lines crossing the pipeline shall maintain a minimum <br />separation of 24 inches between the two lines, and shall remain <br />level across the entire right-of way. <br />F. ^ No loreign appurtenances (meters, poles, drop bones, collection <br />basins, etc.) shall be located on the right-of-way. <br />G. ^ A sin inch wide vinyl burial warning tape shall be placed 12 to 78 <br />inches above the crossing line and extend across the entire <br />right-of-way, as a protective measure. <br />H. ^ A joint trench is the recommended methotl for utilities to cross, <br />and under normal circumstances only requires that one permit <br />be obtained by the excavating company. <br />I. COMMUNICATION LINES (TELEPHONE, N, OTHER DATA <br />Lh4ES) <br />A. ^ Shall meet all provisions for GENERAL REQUIREMENTS - <br />BURIEO LINE CROSSINGS <br />B. ^ Shall be encased in a rigid nonmetallic conduit across the full <br />width o(the right-of--way and buried at constant depth across the <br />right of way(s). <br />C. ^ Fiber optic lines must be encased in PVC or equal conduit and <br />the conduit must be encased with a minimum 5 inch red dye <br />concrete with minimum strength of 2,500 psi across the full <br />width of the right of-way. <br />D. ^ There will be no intentional~grounding within 200 feet of the <br />pipeline. <br />II. BURIED POWER LINES <br />A. ^ Shall meet all of the GENERAL REQUIREMENTS -BURIED <br />LINE CROSSINGS, except for item E. <br />B. ^ Shall have minimum clearances between lines of 24 inches <br />for 0 l0 600 volts; 30 inches for 601 to 22,000 :oils; 36 inches <br />for 22,001 to 40,000 volts; and 42 inches for 40,001 volts and <br />above. <br />0. ^ In the event an underground electric line crosses the pipeline, it <br />will be necessary to install the crossing line in pvc or rigid heavy <br />wall steel conduit with a minimum 5 inch red dye concrete <br />with minimum strength of 2,500 psi across the full width of the <br />right o(•way. <br />D. ^ Signs should be placed at each edge of the right-of-way to mark <br />the underground cable angle and path of crossing. If the <br />underground cable crosses above the pipeline, the signs shall <br />so indicate. These signs are to be furnished by the power <br />company or the encroaching party. <br />III. fiEWER AND WATER LINES <br />A. ^ Shall meet all of the GENERAL REQUIREMENTS -BURIED <br />LINE CROSSINGS. <br />B. [] No manholes or other appurtenances shall be installed in the <br />right of way. <br />C. ^ Septic tanks and drainfelds are not permitted in the right of- <br />way. <br />IV. :iUBSURFACE DRAINAGE TILE (NON-METALLIC) <br />R. Shall meet provisions A, B, E, G & H of GENERAL <br />REOUIREMENTS -BURIED LINE CROSSINGS. <br />V. METALLIC PIPE CROSSINGS EXn~gr! S ~//- <br />W <br />A. ^ All 4 inch and larger metallic pipes crossing Company's <br />pipeline or any metallic pipe transporting potential hazardous <br />material (petroleum, natural gas, etc.) shall have two corrosion <br />test leads installed on Company's pipeline and two on the <br />crossing pipe at the point of intersection. <br />B. ^ Company personnel must install the leads on company's <br />Pipeline(s) antl, if requested, will also install the leads on the <br />crossing pipe. <br />C. ^ Metallic pipe crossings shall have an electrical insulation <br />coating for the full width of the right-of-way. <br />ABOVE GROUND UTILITY LINE CROSSINGS <br />A. ^ Power lines shall maintain a minimum height of 30 feet of <br />clearance over the right-of-way grade. <br />B. ^ Shall have no poles or appurtenances located on the right-of- <br />way. <br />C. ^ Above grountl crossings shall not be above or closer than 200 <br />feet horizontally to any gas escape vent (e.g., relief valve vent <br />station blowdown vent). <br />D. ^ Any pot hole (bell hole) request shall be made through a <br />Company's representative. <br />E. ^ Any facilities laying on or just above the surface on the right of <br />way that would impede the access of company vehicles shall <br />have a vehicular ramp installed over the facilities. <br />Special provisions not addressed in this document shall be listed below <br />or as an attachment labeled as (EXHIBIT "A") attached to this form and <br />initialed by the Permittee. <br />State One Call Contacts <br />Arizona (800) 78&5348 www.azbsrnacom ~; <br />Maricopa County (602) 263-1100 <br />Cali/ornia (800) 227-2600 www.dioaled.oro <br />Colorado (800) 922-1987 www.uncc2.ora <br />Kansas (800) 344-7233 www.kansasonecall.tom <br />Nevada (800) 227-2600 www.usanorth.orc <br />New Mexico (B00) 321.25378 (ALERT) www.nmonecall.org <br />Oklahoma (800) 522-6543 www.callokie.com <br />Texas Lone Star Notification (800) 669-8344 <br />Texas Excavating Safety System (800) 344-8377 <br />Texas One Call (800) 245.4545 <br />Utah (800) 662-4111 <br />Wyoming Wyoming One Call (800) 348-1030 <br />Calf Before You Dig of Wyoming (800) 849-2476 <br />