Laserfiche WebLink
SEDCAD+ CULVERT SIZING UTILITY <br />RPA Culvert <br />~> <br />Design Discharge = 9.020 cfs <br />Entrance Loss Coefficient = 0 <br />9 <br />Pipe Length , <br />40.000 feet <br />Pipe.Slope <br />$ <br />Manning's n - 0.024 <br />Maximum Headwater = 2.000 feet <br />Tailwater Depth - .0.000 feet <br />Smallest Diameter Required to Pass Flow-is 21 inches <br />PERFORMANCE CURVES: <br />Diameter: 15 inches <br />i~ <br />Headwater Discharge Flow <br />____ <br />--------- ___(cfs) <br />------ Control <br />--------------- <br />- <br />Type <br />0.20 0.00 -- ------- <br />~---- <br />0.40 1.27 .outlet i <br />0.60 1.54 Outlet i <br />0.80 1.82 outlet 1 <br />1.00 2.26 Outlet 1 <br />1.20 3.04 Outlet 1 <br />1.40 3.81 Outlet i <br />1.60 4.29 Outlet 2 <br />1.80 4.67 Inlet 4 <br />2.00 5.05 Outlet 6 <br />2.20 5.40 Outlet 6 <br />2.40 5.75 Outlet 6 <br />2.60 6.08 Outlet 6 <br />2.80 6.38 Outlet g <br />__ -3.00 -_ _-6.67,_- _-Outlet 6 <br />Diameter: 18 inches <br />Flow <br />Type <br />0.20 0.00 0---- <br />0.40 1.81 Outlet 1 <br />0.60 2.21 Outlet i <br />0.80 2.57 Outlet 1 <br />1.00 2.93 Outlet 1 <br />1.20 3.65 Outlet 1 <br />1.40 4.61 Outlet 1 <br />1.60 5.68 Outlet 1 <br />1.80 6.49 Inlet 3 <br />2.00 7.17 Outlet 6 <br />2.20 7.78 Outlet 6 <br />2.40 8.35 Outlet 6 <br />2.60 8.89 Outlet 6 <br />2.80 9.38 Outlet 6 <br />3_00 9.86_- Outlet 6 <br />Headwater Discharge <br />(ft) (cfs) Control <br />Diameter: 21 inches <br />i <br />Permit Renewal No. 3 <br />Headwater Discharge Flow <br />`_-__(ft) __(cfs)` _-Control _ TYp <br />0.40 2 <br />37 - <br /> . Outlet Subcritical i <br />0.60 2.98 outlet Subcritical i <br />0.80 3.49 Outlet Subcritical 1 <br />1.00 3.99 Outlet Subcritical 1 <br />1.20 4.54 outlet Subcritical <br />1.40 5.22 Outlet Subcritical i <br />TAB 3.15, PG 6 ~ 1~1~99 <br />