Laserfiche WebLink
Table 2 <br /> <br />~~ CULVERT LAYOUT DETAIL <br />• <br /> Drainage Culvert Loyout Details Inlet Head above <br /> Basin Diameter Length S ope Bottom of Pipe (feet) <br />1 <br /> <br />Designation <br />(inches) <br />(feet) (%) <br />Avai a e ) <br />Required <br /> (1) (2) (3) (4) (5) (b) <br /> A 36 120 5 12.0 2.6 <br /> B 48 120 5 10.0 2.5 <br /> C 48 120 5 8.4 2.6 <br /> D 36 95 8 6.7 2.3 <br /> E 36 105 4 8.0 2.4 <br /> F 30 100 5 14.5 3.9 <br /> G 30 100 3 21.0 4.1 <br /> H 30 120 5 9.8 3,2 <br /> I 30 100 7 17.7 1.8 <br /> J 30 110 12 15.5 2.0 <br /> K 30 100 2 6.8 3.5 <br /> L 30 90 8 6.3 3.2 <br /> M 36 85 3 9.8 2.7 <br /> N 48 120 5 19.0 2.1 <br /> O 24 80 5 2.5 2.4 <br /> P 18 70 6 4.8 4.2 <br /> Q 30 100 1 10.6 3.3 <br />` R 30 60 1 3.0 I.0 <br /> S 30 80 5 3.5 1.2 <br /> T 24 60 20 3.0 1.2 <br /> V 24 40 1 2.5 1.6 <br /> W 18 20 1 3.5 2.0 <br /> Taylor Creek 120 250 6 18.0 7.1 <br />(1) Required inlet heads for design <br />discharges given in Table 1 <br /> <br />