Laserfiche WebLink
c~LB~n~D Enkamat 7018 R2M <br />Root Reinforcement Mat <br />Description Enkamat® 7018 is athree-dimensional turf reinforcement mat (TRM) made of continuous <br />monofilaments fused at their intersections. Ninety-five (95%) percent of the Enkamat is <br />open and available for soil, mulch and root interaction with filaments, creating the most <br />effective Root Reinforcement Mat (RZM) available. Enkamat is manufactured from nylon <br />to eliminate the buoyancy factor associated with submerged conditions and provide per- <br />manent TRM protection in vegetated channels as well as on slopes <br />Recommended • Permanent erosion control for Green (vegetated) channels with expected shear <br />Applications stresses 5 9 psf. <br />• Permanent erosion control for slight to moderate slopes (<_ 2H:1V). <br />• Support and enhance performance of Ecosystem plants. <br />• Substrate for hydraulically applied Bonded Fiber Matrix (BFM) and other mulches for <br />erosion control applications where low water flow and low to moderate shear stresses <br />are expected. <br />Technical Data MechanicatProperties ~,- TesfMethod Units ..TypicaLRollValue <br />MD CD <br />Tensile Strength (modified) VyJ kN/m (Ibs/ft) 2.2 (150) 1.3 (90) <br />Thickness ASTM D 5199 mm (in) 16.5 (0.65) <br />Mass/Unit Area ASTM D 5261 ct/m` (oz/vd`) 290 (8.6) <br />UV Stability ASTM D 5035 % strength 80 <br />,,„,,,,;,;o,,y retained <br />Performance,Properties TistMethod ,' Units, ;;T.ypicaCRolhValue_ -, <br />Permissible Velocity <br />Product Only Flume test' m/s (Ws) 6,1 (20) <br />30 minute, vegetated Flume test' m/s (fVs) 5.8 (19) <br />50 hour, vegetated Flume test' m/s (iUs) 4.2 (14} <br />Permissible Shear Stress <br />Product Only Flume test' kN/m` (Ibs/ft`) 0.53 (11.2) <br />30 minute, vegetated Flume test' kN/mz (Ibs/ftz} 0.43 (9.0) <br />50 hour, vegetated Flume test' kN/m2 (Ibs/ftZ) 0.34 (7.0) <br />1. Flume test pert°rmetl al Independent laboratory-data and tlataib awilable upon request <br />Packaging Data Physical Properties iUmts :=` ` Nomirial Value ''' <br />Rolf Dimensions m 0.99x84.4 1 93 x 27.5 <br />(width x length] (ft) (3.25 x 277) (6.33 x 90) <br />Roll Area m2(yd2) 83.6 (100) 53 (63.3) <br />Estimated Roll Diameter cm (in) 109 (43) 61 (24) <br />Estimated Roll Weight kg (Ib) 25 (54) 15 (34) <br /> To the best our knowledge, the inf°rrnation contained herein u eccu2te. However, Colbond Inc. cannot assume any liabil- <br />COlbond InC, ity whatsoever far Ne accuraty or completeness thereat. FMuI determination o/ the suitabNiN of arty inlormatian or material <br />PO Box 1057 for Ne use contemplaleq of its manner of use and wheNer the suggested use infnnges any palen5 is the sole responsibil- <br />Enka, NC 28728 ib of the user. Colbond Inc. 2004® <br />Tel 800-365-7391 <br /> <br />Fax 828-665-5009 09 / 2004 <br />www.colbond-usa.com ClV70187DS03 <br />