Laserfiche WebLink
E~2 <br />REMARKS: <br />This well was drilled and completed identical to E-1-88. <br />It had a successful casing and packer completion into the <br />roof of the Entry #1 at the intersection of crosscut 11. <br />It was to be coupled at the surface with E-1-88 with a large <br />vacuum pump and used to ventilate the workings, if <br />necessary. <br />E-1-A <br />REMARKS: <br />This well is located within 60 feet of GE 33-88 and GE <br />35-88. It was first drilled to 440 feet and cased with <br />cement grouting. It was then "open hole" drilled into the <br />active workings at the closest point of the fault and gas <br />inflow. It was completed as a methane gas ventilation well <br />without water production and plans were made to install a <br />vacuum pump or fan at the surface to stimulate <br />degasification. <br />• <br /> <br />2.04-6(k) (Revised 09/01/89) <br />