III IIIIIIIIIIIII III <br />99_9 <br />~~~ MINE AREA PONDS Doc Date:72/11/2001 <br />• <br />GENERAL DESCRIPTION <br />There are three (3) sedimentation ponds and two (2) water storage ponds which <br />presently exist within the Southfield Mine area. Specifically, the ponds within the <br />mine area are: <br />- Sedimentation Pond No. 1 <br />- Water Treatment and Recycle Pond No. 2 <br />- Freshwater Pond No. 3 <br />- Sedimentation Pond No. 4 <br />- Sedimentation Pond No. 5 <br />All sedimentation ponds are designed to contain surface runoff produced by the <br />10-year, 24-hour event and the required sediment yield. Each sedimentation pond <br />contains an emergency spillway designed to safely pass the peak discharge from <br />the 25-year, 24-hour event while maintaining on foot minimum freeboard. Ponds <br />2 and 3 are used in the preparation plant water-use system and are not designed <br />to contain surface runoff or sediment. <br />Each of the above mentioned ponds has been designed, approved, and certified <br />after construction. The SEDCAD+ computer model was utilized to design or <br />confirm the function of each pond. SEDCAD+ calculations for Sediment Ponds <br />Nos. 1, 4 and 5 are included in this exhibit. <br />All mine area ponds are shown on the Drainage and Sediment Control Map, (Map <br />20). Detailed design drawings for each pond are also contained in the permit and <br />are referenced, as appropriate, in this exhibit. <br /> <br />11 Revised M10/96 <br />Minor Revision No. 30 <br />