Laserfiche WebLink
<br />~t <br />TEST NO.: 1, LA 264 <br />ZONE TESTED: Overburden <br />TYPE OF TEST: Pumping <br />Total Depth-ft <br />Diam. of Bit-ft <br />Diam. of Csg.-ft <br />Elev. of TOC-ft <br />Depth to Static Water-ft <br />Elev. of Static lJater-ft <br />Pumping Time-minutes <br />Total Volume Pumped-ft3 <br /> <br />L <br />e <br />TABLE 63 '~,l <br />,; <br />~rlell LA 264 <br />297 <br />0.50 <br />0.34 <br />7090 <br />50.93 <br />7039 <br />148 <br />263.7 <br />Remarks: Surface casing set at 30.9 ft. Four inch steel casing set at <br />291 ft. with bottom capped and perforated from 62 ft. to Z76 <br />ft. ldater was encountered at about 12 ft. during drilling. . <br />Estimated discharge during drilling was 15 gpm. No noticeable <br />increase in discharge over the interval between 72 ft. and <br />297 ft. Pump was set at 80 ft. During first 5 minutes of <br />test, pump discharge was throttled. Pump discharge was in- <br />creased to capacity at 6 minutes into the test. 'f hereafter <br />pump discharge remained constant within +1 percent at 1.99 <br />ft3/min. <br />Elapsed Time Drawdown <br />t, minutes s, ft <br />0 ~ 0 <br />0.95 0.88 <br />2.00 1.01 <br />5.02 1.26 <br />10.77 3.56 <br />14.27 4.30 <br />18.65 4.88 <br />25.03 5.55 • <br />32.63 6.14 <br />