Laserfiche WebLink
COLVERT 50 <br />SEDCAD+ CULVERT SIZING UTILITY <br /> <br />Design Discharge = <br />Pipe Length = <br />Pipe Slope = <br />Manning's n = <br />Max. Headwater = <br />1.450 cfs <br />120.000 feet <br />3.000 $ <br />0.025 <br />1.800 feet <br />RESULTS: <br />• <br />Exhibit 18 <br />Inlet Control: 8 inch Diameter <br />Full Pipe Flow: 9 inch Diameter <br />Revised 12/8/89 <br />-314- <br />