Laserfiche WebLink
• Structural Number Verification <br />(AASHTO Design of Pavement Structure - 1986) <br />HAUL ROADS <br />Traffic: Design 18 kip ESAL: 120,000 <br />Reliability: 50 percent <br />Overall Deviation: 0.40 <br />Soils: Resilient Modulus, 5000 psi <br />PSI Loss Due To Traffic: 2.0 <br />Required Structural Number = 2.26 <br />ACCESS ROADS <br />Traffic: Design 18 kip ESAL: 6,500 <br />• <br />Reliability: 50 percent <br />Overall Deviation: 0.40 <br />Soils: Resilient Modulus 5000 psi <br />PSI Loss Due To Traffic: 2.0 <br />Required Structural Number = 1.36 <br />Required Gravel Sections <br />Haul Road B Extension <br />Minimum Structural Number(MSN) required = 2.26 <br />Average Existing Road Base Section = 7.5" (fair condition) <br />Existing Subbase Gravel Section = 12" (fair condition) <br />Existing Structural Number (ESN) = 7.5 (0.10) + 12(0.08) = 1.71 <br />Required Structural Number = MSN -ESN = 2.26 - 1.71 = 0.55 <br />. Grave[ Section Required => 0.55/0.14 = 3.9 => <br />Use 4 inches of Class V I Base Course. <br />