Laserfiche WebLink
CHANNEL INSTALLATION <br />NORTH <br />AMERICAN ~~ <br />GREEN <br />EROSION CONTROL Products <br />Cuoronteed SOLUTIONS <br />14649 HIGHWAY 47 NORTH <br />LVANSVILLE, IN 47725 <br />800-772-2040 <br />www.nagreen.com <br />~ >,~~I ~ <br /> <br />= 1z.s cM) <br />1. PREPARE SOIL BEFORE INSTAWNG ROLLED EROSION CONTROL PRODUCTS (RECP'a), INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. <br />NOTE: WHEN USING CELL-O-SEED DO NOT SEED PREPARED ARE0. CELL-O-SEED MUST BE INSTALLED WRH PAPER 510E DOWN. <br />2. BEGIN AT THE TOP OF THE CHPNNEL tA' ANCHORING THE RECP's IN A 6" (15 CM) DEEP X fi" (15 CM WIDE TRENCH WffH APPROXIMATELY 12" 30 CM) OF RECP'e <br />EXTENDED BEYOND THE UP-SLOPE PORTION OF THE TRENCH. ANCHOR THE kECPB WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30 CM APART IN THE <br />BOTTOM OF THE TRENCH. BACKFILL AND COMMCT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMNNING 12" (30 CM) PORTION OF <br />RECP's BACK OVER SEED AND COMPACTED SOIL. SECURE RECP's OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30 CM) <br />ACROSS THE WIDTH OF THE RECP's. <br />3. ROLL CENTER RECP'e IN DIRECTION OF WATER FLOW IN BOTTOM OF CHANNEL RECP'e WILL UNROLL WRH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. PLL <br />RECP's MUST BE SECURELY FASTENED TO 6011 SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. <br />HEN USING THE DOT SYSTEM, STAPLES/STARES SHOULD BE PLACED THROUGH EACH OF THE COLORED D07$ CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. <br />APART ANDS4C (10 CM)CON CENTER 0 SECUREI RECP'a~.n~ WITH A 4' - 6' (10 CM -15 CM) (NERUP. USE A DOUBIF ROW OF STMLTS STAGGERED 4" (10 CM) <br />5. FULL LENGTH EDGE OF RECP's AT TOP OF SIDE SLOPES MUST BE ANCHORED WffH A ROW OF STAPLES/STAKES APPROXIMATELY tY (30 CM) MART IN A 6" (15 CM) <br />DEEP X 6" (15 CM) WIDE TRENCH. BACKFlLL AND COMPACT THE TRENCH AFTER STMUNG. <br />6. ADJACENT RECPb MUST BE OVERLAPPED MPROXIM4IELY 2' - 5" (5 CM -12.5 CM) (DEPENDING ON RECP's TYPE) AND STMLED. <br />7. IN HIGH FLOW CHANNEL MPUCATIONSL A STMLE CHECK SLOT IS RECOMMENDED AT SO TO 40 FOOT (9 M - 12 M) INTERVAL6. U6E A DOUBLE ROW OF STMLES <br />STAGGERED 4" (10 CM) MART AND 4 (10 CM) ON CENTER OVER ENTIRE WIDTH OF THE CH4NNEL <br />8. THE TERMINAL END OF THE RECP'a MU57 BE ANCHORED WfTFI A ROW OF STAPLES/STAKES MPROXIMATELY 12" (30 CM) MART IN A 6" (15 CM) DEEP X 6" (15 CM; <br />WIDE TRENCH. BACKFlLL AND COMPACT THE TRENCH AFTER STMLING. <br />NOTE: <br />• IN LOOSE SOIL CONDITIONS. THE USE OF STMLE OR STAKE LENGTHS GREATER THAN 6" (15 CM) MAY BE NECESSARY TO PROPERLY ANCHOR THE RECP's. <br /> NOTE: <br />A CRITICAL POINTS • HORIZONTAL STMLE SPACING SHOULD BE ALTERED <br /> F NECESSARY TO ALLOW STMLES TO SECURE THE <br />A OVERLAPS AND SFAIAS <br />C . <br />LRRIC4L POIN75 ALONG THE CH4NNEL SURFACE. <br />B. PROJECTED WATER LINE <br />C. CHANNEL B0T70M/SIDE • IN LOOSE SOIL CONDITIONS, THE USE OF STMLE <br />SLOPE VERTICES OR STAKE LENGTHS GREATER THAN 6" {75 cm) MAY <br /> BE NECESSARY TO PROPERLY ANCHOR THE RECP'a. <br />u <br />REV, 01/05 <br />