Laserfiche WebLink
' Drafi: March 24, 1999 • ~ Page 12 <br />' Table 4. Process Monitoring Schedule <br />' <br />Parameter <br />Monitoring Recording <br />Frequency <br /> Test Well <br />' Injection Pressure Automatic ] 0 minutes <br /> Injection Temperature Automatic ] 0 minutes <br /> Injection Specific Gravity Automatic ] 0 minutes <br />' Injection Flow Automatic 10 minutes <br /> Dischazge Pressure Automatic 10 minutes <br />' Dischazge Temperature Automatic 10 minutes <br /> Dischazge Specific Gravity Automatic 10 minutes <br />' Discharge Flow Automatic 10 minutes <br /> Process Heater <br /> Temperature Automatic ]0 minutes <br />' Steam Temperature Automatic 10 minutes <br /> Flow Automatic 10 minutes <br />' Nitrogen Cap <br /> Nitrogen Consumption Manual daily <br />' Pressure Automatic ] 0 minutes <br />S.O QUALITY ASSURANCE/QUALITY CONTROL <br />Water quality laboratory analyses will be conducted in accordance with a plan approved by <br />' the BLM. A comprehensive quality assurance and quality control (QA/QC) program for water <br />quality sampling and analysis is currently under development by American Soda. The plan will <br />' include, but will not be limited to, collection and analysis of duplicate samples, trip blank samples, <br />equipment blank samples, and quality control samples. The water quality QA/QC plan will include <br />t standazdized procedures for sample collection, shipping prepazation, holding times, and sample <br />chain-of-custody protocol. A State ofColorado certified laboratory will be used focal] off-site water <br />' quality analysis. American Soda will maintain afull-time environmental coordinator who will <br />assure adherence to the QA/QC plan. <br />1 <br />1 <br />Agapito Associates, Inc. <br />1 <br />