<br />Stipulation No. 16 <br />WITHIN 6 MONTHS OF PERMIT APPROVAL, THE PERMITTEE MUS1^ <br />INSTALL A 21 INCH OR LARGER CULVERT AT STATIOIJ 12+50 OF <br />THE NORTHERN N0. 1 HAUL ROAD. IN ADDITION, THE PERMITTEE <br />MUST SUBMIT A PLAN FOR DIVISION APPROVAL TO BRING THE <br />EIGHT 36 INCH CULVERTS AT STATION 31+50 OF THE NORTHERN <br />N0. 1 HAUL ROAD INTO COMPLIANCE WITH THE SIZING REQUIRE- <br />D9E14TS OF RULE 4.03.1(4)(e)(i). THE PLAN MUST BE IMPLE- <br />MEi4TED WITHIN 30 DAYS OF DIVISION APPROVAL. <br />Northern Coal's Answer: <br />A 21 inch or larger culvert will be installed in the <br />Northern No. 1 Haul Road as requested. <br />Calculations performed by a Registered Engineer (copy <br />attached) show that the eight 36 inch culverts are capable <br />of passing a 10 year 24 hour. event. Should an event <br />greater than this occur, the excess flow would be diverted <br />along the Haul Road in a ditch, through culverts and into <br />the natural drainage of Curtis Creek. Since the haul road <br />is 1.5 feet higher than the top of the culverts in question, <br />there will be no chance of the water topping the road in <br />the case of a 20 year 24 hour event. By allowing the excess <br />water to travel in the ditch along the haul road, erosional <br />damage will be kept to a minimum on surrounding areas. <br />1 <br />~~ <br />~~~ c1, \~ <br />n^` <br />,~~, <br />C~• <br />