Laserfiche WebLink
III IIIIIIIIIIIII III NORTHWEST COLORADO CONSULTANTS, INC. <br />Project: Haul Road Y-A Project No.: 95-2384 <br />Location: Hayden, Colorado Report No.: 1 <br />Client: Seneca Coal Company <br />Work Performed: <br />Date: 8/10/95 <br />Time: 2.0 <br />Mileage: 30 <br />EngrJTech: JK/HS <br />As requested, we visited the project site antl conducted nuclear density test No.'s 1 through 4 on the material <br />being placed for subgrade fill. During our visit, fill was being placed and compacted around the 36" CMP at Sta. <br />8+40. <br />Remarks: <br />The material tested generally met project specifications with moisture contents being 0.9% above to 4.0% below <br />optimum. The contractor was advised to moisten the material. A sample was obtained and returned to our <br />laboratory for checkpoint Proctor deterrnination.c The results did not match any previous curve for this proiect; <br />therefore, a Standard Proctor and classification test (Sample #1) was perormed. <br />Please refer to the attached sheet for results of today's testing. <br />Verbal Discussions: <br />Chuck McCulloh of Seneca Coal Co. was notified of today's test results. <br />