rrtl_.m~l"L t'.l:Lat'G->3 • TO~KCNICR FnX ~ :-UG LB. !-:~ S~'c2PY. .'~_P.! <br />~ "_ <br />Mhen liquid flow has ceased such that continued pressure filtration at 50 <br />p;i does got result to any additional fllirate within a 2-minute oerlod, <br />stop the filtration. i.iose the liquid inlet/outlet valve, discontinue <br />pressure to the piston, and disconnect and weigh the filtrate coilec*.ian <br />container. <br />NOTE: Instantaneous application of high pressure can degrade the glass fiber <br />filter ar.d .-ay cause prar~ature plugging. <br />7.3.10 The material in the ZHE is defined as the solid phase of <br />the sample and the filtrate is defined as the liquid phase. <br />NOTE: Some samples, such as oily wastes and some paint wastes, will obviously <br />contain some material which appears to be a liquid. Even after applying <br />pressure filtration, this material will not filter. If this is the case, <br />the material within the filtration device is defined as a solid, and is <br />carried through the 1312 extraction as a solid. <br />If the original waste contained <0,5 :dry sclids (see Step 7.1.2), <br />this filtrate fs defined as the 1312 extract and is analyzed directly, <br />Proceed to Step 1.3.15. _ <br />7.3.11 The liquid phase may now be either analyzed immediately <br />(see Steps 7.3.13 through 7.3.15} or stored at 4'C under minimal headspace <br />conditions until time of analysis. Determine the weight of extraction <br />fluid ~R3 to add to the ZHE as follows: <br />weight of extraction fluid = <br />20 x ': solids (Step 7,1.1) x weight <br />of waste filtered (Step 7.3.4 or 7.3.8} <br />100 <br />7.3.12 The following steps detail how to add the appropriate <br />amount of extraction fluid to the solid material within the ZHE and <br />agitation cf the ZHE vessel. Extraction fluid M3 is used in all cases <br />(see Step 5.1). <br />7.3.12.1 with the ZHE in the vertical position, attach a <br />line from the extraction fluid reservoir to the liquid inlet/outlet <br />valve. The line used shall contain fresh extraction flu td and <br />should be preflvshed with fluid to eliminate any air packets in the <br />line. Release gas pressure on the ZHE piston (from the gas- <br />inletjoutlet valve), open the liquid inlet/outlet valve, and begin <br />transferring extraction fluid (by pumping or similar means) into.. <br />the ZHE. Continue pumping extraction fluid into the ZHE until the <br />appropriate amount of fluid has been introduced into the device. <br />).3.12.2 After the extraction fluid has been added, <br />immediately close the liquid inlet outlet valve .and disconnect the <br />extraction fluid line. Check the ZHE to ensure that all valves are <br />to their closed positions. Manually rotate the device in an <br />end-over-end fashion 2 or 3 times. Reposition the ZHE in the <br />1312 - lfi Revision 0 <br />November 1992 ~ <br />