r <br />i <br />NaTec <br />ATTACHMENT 1 <br />NaTec Monitoring Well Monitoring Plan <br />NaTec personnel will sample the wells with dedicated samplers <br />from completion .one. Nitrogen gas will be utilized to air lift <br />the samples. Samples are obtained after at least one evacual.i.on <br />of the sample zone to obtain a fresh aquifer sample. Field <br />measurements will. be noted throughout evacuation (first cycle) <br />and subsequesnt cycle(s) to determine when water quality <br />stabilizes and theerefore when to obtain the water sample. <br />Pield Measurements 1'Monthly) by NaTec Samples - 1 <br />temperature pH conductivity <br />Lab Analyses - Maior Components (Ouarterlvl by Contract Lab. Samples - 2 <br />total dissolved solids <br />potassium <br />alkalinity <br />sodium <br />silica <br />chloride <br />magnesium <br />fluoride <br />calcium sulfate boron strontium <br />Minor Components (Sample initially and annually) by Contract Lab, <br />Samples - 3 (Maior a.nd Minorl <br />arsenic aluminum cadmium <br />manganese selenium barium <br />chromium nickel vanadium <br />beryllium copper lead <br />molybdenum mercury bromide <br />zinc <br />lithium nitrate organic N <br />sulfide nitrogen ammonia <br />iron sulphate total phosphate <br />Dissolved Organic Carbon (DOC) silica <br />