Laserfiche WebLink
Metal Mining SWMP Guidance Document <br />Page 10 <br />include a description of the results of any evaluation for the presence of discharges other than <br />stormwater, the method used, the date of any evaluations and the on-site drainage points that <br />were directly observed during the evaluation. <br />A number of discharges other than stormwater may not require a CDPS Wastewater <br />Discharge permit and are considered Allowable Non-stormwater Discharges. These are <br />listed at Parl LD.3, below. Any of these discharges that exist at the site must be identified <br />in the SWMP. <br />In other words, only stormwater can be conveyed by the stormwater drainage system. Examples of potential <br />illicit connections include the floor drains and toilets in maintenance buildings, chemical storage buildings, etc. <br />Most illicit connections involve older buildings which were constructed when such connections may not have <br />been prohibited. Therefore, management or tenants may have no knowledge of them. Cross-connections via <br />broken lines or stoppages are also possible. <br />There are several methods of determining whether or not illicit connections exist. Dry weather observations of <br />outfalls or other appropriate locations is the most common method of determining whether or not non- <br />stormwater dischazges are occurring. Other acceptable procedures include analysis and validation of accurate <br />piping schematics, dye tests, etc. <br />In general, it is not anticipated that non-stormwater dischazges will be a problem at most mine sites <br />Note - if illicit connections are discovered, corrective measures must be taken. <br />The following paragraphs from Part I.D.3 of the permit and describe Allowable Non-stormwater Dischazges. If <br />any of these discharges exist at the site they must be identified in the SWMP. <br />a. Except as provided in pazagraph b, below, all discharges authorized by this permit shall be <br />composed entirely of stormwater. Dischazges of material other than stormwater must be addressed <br />in a sepazate CDPS permit issued for that dischazge. <br />b. Dischazges from the following sources that aze combined with stormwater dischazges associated with <br />mining activity may be authorized by this permit, provided that the non-stormwater component of the <br />dischazge is identified in the SWMP (see Part I.A.3.d of the permit): fire fighting activities, <br />uncontaminated natural springs, and irrigation return flow. <br />In other words, the water being conveyed by your storm drain system can only be composed of stormwater or <br />runoff from fire fighting activities, unless the SWMP identifies any of the other sources of flow <br />(uncontaminated natural springs, irrigation return flow) as being a component of it. <br />5. Comprehensive Ins ep coon <br />The SWMP shall identify qualified personnel that shall inspect designated equipment and mine areas <br />at appropriate intervals specified in the plan, at least twice a year (in the spring and fall). The <br />operator shall keep a record of such inspections. This record shall be made available to the Division <br />upon request and summarized in the Annual Report (see Part LE.1 of the permit). <br />