Laserfiche WebLink
Bulkhead Design •• <br />Page 1 . <br />Flexure Notattion Summary: <br />a = depth of equivalent rectangular stress block. <br />As = area of tension reinforcement (sq in). <br />b = width of compression face of member. <br />c = distance from extreme compression fiber to neutral axis. <br />C = sum of compressive stresses in the concrete. <br />f = effective depth, the distance from extreme compression fiber to <br />centroid of tension reinforcement. <br />f'c =specified compressive strength of concrete (psi). <br />fs = calculated stress in reinforcement at service loads. <br />fy = specified yield strength of reinforcement (psi). <br />h = total depth or thickness of member. <br />M, = theoretical moment strength of section (in-lb). <br />Mu = applied design moment at a section. <br />T = sum of tensile stresses in the reinforcement. <br />r,', = a coefficient relating the depth of the rectangular stress block to <br />the depth from the compression face to the neutral axis, a = x c. <br />~~ = ratio tension reinforcement = As/bd <br />J = reinforcement ratio producing balanced conditions. <br />,, <br />.-?._, =maximum reinforcement ratio = 0.75 <br />,;,.,- =minimum reinforcement ratio = 200/ <br />C = capacity reduction factor. <br />~_ . <br />.~.. 1 ~ ~ <br />_ ~ =;~' <br />