Laserfiche WebLink
<br />Wolf Creek Seam <br /> <br />The lowest coal in the Williams Fork Formation of the Mesaverde Group is the <br />Wolf Creek Seam. The Wolf Creek Seam is the first aquifer encountered below <br />the bottom of the proposed mine pit. <br />Depth to water and water quality measurements have been made at three sites in <br />and adjacent to the permit area. Water levels in the Wolf Creek at all three <br />sites exhibit confined conditions. Dependent upon proximity to the outcrop <br />recharge area (paralleling the Sage Creek anticlinal axis), and upon local <br />structure, each well has varying amounts of head. The well located furtherest <br />from the anticlinal axis (Well GW-42-S2W-2WC) is the well which exhibits the <br />most head with the amount of head decreasing at the other wells in response to <br />decreased distance to the recharge area. The strata dip so steeply in the <br />area of the Seneca II-W Mine that the maximum amount of head has been observed <br />as 770 feet in the downdip well. This head has also caused artesian surface <br />flow. <br />Ground water flows from the recharge to the discharge, or in this case from <br />the anticlinal axis to the center of the basin. Therefore, the major <br />component of flow appears to be toward the west. <br />Aquifer tests were performed on the two updip wells during the summer of <br />1980. These tests indicate that the Wolf Creek is a fairly well confined <br />aquifer which transmits limited amounts of water. One well was pumped at an <br />average of 1.2 gallons per minute for about 3 1/2 hours, and produced no <br />observable drawdown at an observation well 20 feet away. Transmissivity <br />values calculated for the Wolf Creek range from 0.02 Ft2 per day (0.149 <br />gallons per day per foot) for well 3WC, and 0.001 Ft2 per day (0.007 gallons <br />per day per foot) in the two wells tested. Due to the low water yield and <br />transmissivity values, the storativity value of the Wolf Creek Seam is <br />estimated to be about 1 X 10-5. These values, both transimissivity and <br />storativity, would appear to be quite low. Aquifer test data, however, does <br />substantiate these values. Due to the highly lenticular and discontinuous <br />nature of the Mesaverde Group, it is thought that transmissivity and <br />storativity will be aereally variable. <br />The quality of Wolf Creek Coal water is slightly acidic, very hard and saline. <br />Based on data presented, the water type changes from calcium/sulfate to <br />sodium/bicarbonate down gradient. Total dissolved solids (TDS) values exceed <br />U.S. Environmental Protection Agency drinking water standards at all three <br />Wolf Creek wells at various sample times. TDS criteria for livestock use has <br />been met at all wells, while its use as irrigation water is marginal due to <br />adverse effects on many crops. These criteria also have been established by <br />the EPA. <br />As previously stated, Well 2WC is located down gradient, and has the lowest <br />levels of TDS and sulfate, indicating that the sulfate is being precipitated <br />from the water as it moves down gradient. <br />Well 3WC displayed the only case of elevated iron levels within the Wolf Creek <br />Coal. <br />-17- <br />