My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REV103200
DRMS
>
Back File Migration
>
Revision
>
REV103200
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2016 1:14:00 AM
Creation date
11/22/2007 1:04:06 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981019
IBM Index Class Name
Revision
Doc Date
3/10/1992
Doc Name
PN C-81-019 PR-01
From
COLOWYO COAL CO
To
MLRD
Type & Sequence
PR1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />~® <br />CTL/THOMPSON, INC. <br />CONSULTING GEOTECHNICAL AND MATERIALS ENGINEERS <br />February 14, 1992 <br />Colowyo Coal Company. <br />5731 State Highway 13 <br />Meeker, CO 81641 <br />Attention: Mr. Jim Kiger <br />Subject: Supplemental Slope Stability Analysis <br />West Pit Excess Spoil Pile <br />Colowyo Mine <br />Moffat County, Colorado <br />Job No. 18,349 <br />Gentlemen: <br />We have performed additional slope stability analysis to confirm stability of the <br />West Pit Spoil Pile. These analyses supplement those in our previous report (Job <br />No. 16,516, dated March 1, 1991). This letter contains laboratory test results, the results <br />of our analyses, and conclusions regarding the stability of the West Pit Pile. <br />We were provided a sample of clay Colowyo employees obtained from the general <br />area of TH-1 from the previous investigation, This sample represents the clay fill which <br />is to be compacted to at least 90% of maximum modified Proctor dry density below the <br />toe of the spoil pile. A Proctor compaction test (ASTM 1557-78A) indicated a maximum <br />dry density of 119 pcf and an optimum moisture content of 12.5% for the clay (Fig. 1). <br />We performed a consolidated, undrained triaxial test with pore pressure measurements <br />on a sample of clay which was remolded to 90°,6 of maximum dry density. Figure 2 <br />shows the triaxial test results. The friction angle (~) and the cohesion intercept (c) were <br />calculated from this data as 28° and 650 psf; respectively. <br />A stability analysis was executed using the Geoslope "Stahl" computer program <br />from Geocomp, Inc. This analysis was run with the soil properties determined for the <br />various soils in this investigation and the previous investigation. The soil profile <br />considered in this analysis was representative of the design. The analysis assumed <br />natural clays at the toe of the pile would be removed and replaced with compacted clay <br />fill. The spoil was then placed above the clay fill layer. Groundwater was assumed at the <br />top of the clay fill. This profile exhibited a computed factor of safety of 2.0. Figure 3 <br />shows the profile and the ten most critical failure surfaces with the most critical denoted <br />by the number 1. <br />971 wE5-:2TH .:VBdUE DENVER CCLCRnD0502C- ~?p379350::7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.