Laserfiche WebLink
.' <br />3.0 INTERFERENCES <br />I <br />' 3.1 Potential interferences that may be encountered during ~malysis are <br />~: , discussed in the individual analytical methods. <br />~ 4.0 APPARATUS AND MATERIALS <br />;~ 4.1 Agitation apparatus: The agitation apparatus must be capable of <br />rotating the extraction vessel in an end-over-end fashion (see Figure 1) at 30 <br />± 2 rpm. Suitable devices known to EPA are identified in Table 2. <br />' =. 4.2 Extraction Vessels <br />', 4.2.1 Zero Headspace Extraction Vessel (ZHE). This device is for <br />use only when the sample is being tested for the mobility of volatile <br />analytes (i_e., those listed in Table 1). The ZHE (depicted in Figure 2) <br />allows for liquid/solid separation within the device and effectively <br />precludes headspace. This type of vessel allows for initial liquid/solid <br />separation, extraction, and final extract filtration without opening the <br />vessel (see Step 4.3.1). These vessels shall have an internal volume of <br />' 500-600 ml and be equipped to accommodate a 90-110 mm filter. 'Fhe devices <br />contain VITON°~ 0-rings which should be replaced frequently. Suitable ZHE <br />devices known to EPA are identified in Table 3. <br />I For the ZHE to be acceptable for use, the piston within the ZHE <br />should be able to be moved with approximately 15 psi or less. :[f it takes <br />more pressure to move the piston, the 0-rings in the device should be <br />replaced. If this does not solve the problem, the ZHE is unacceptable for <br />1312 analyses and the manufacturer should be contacted. <br />t The ZHE should be checked for leaks after every extracti~m. If the <br /> device contains a built-in pressure gauge, pressurize the de~~ice to 50 <br /> psi, allow it to stand unattended for 1 hour, and recheck the pressure. <br /> If the device does not have a built-in pressure gauge, pressurize the <br />' device to 50 psi, submerge it in water, and check for the presence of air <br /> bubbles escaping from any of the fittings. If pressure is lost, check all <br /> fittings and inspect and replace 0-rings, if necessary. Retest the <br /> device. If leakage problems cannot be solved, the manufacturer should be <br /> contacted. <br /> Some ZHEs use gas pressure to actuate the ZHE piston, while others <br />'' use mechanical pressure (see Table 3). Whereas the volatiles procedure <br /> (see Step 7.3) refers to pounds-per-square-inch (psi), for the <br /> mechanically actuated piston, the pressure applied is measured in torque- <br />' inch-pounds. Refer to the manufacturer's instructions as to the proper <br /> conversion. <br /> 4.2.2 Bottle Extraction Vessel. When the sample is being <br /> evaluated using the nonvolatile extraction, a jar with sufficient capacity <br /> to hold the sample and the extraction fluid is needed. Headspace is <br /> allowed in this vessel. <br />' ~VITON® is a trademark of Du Pont. <br /> 1312 - 2 Revision 0 <br /> November 1990 <br />