Laserfiche WebLink
C. CONTRACTOR shall grade all excavations to enswe grades are maintained to provide <br />adequate drainage at all times. Work shall be suspended by CONTRACTOR when, in the <br />opinion of MANAGER and CERTIFYING ENGINEER, the site is overly wet, muddy, or <br />otherwise unsuitable for proper maintenance, until directed otherwise by MANAGER, at no cost <br />to CC&V. <br />D. In excavations where Structuml Fill or Select Structural Fill is to be placed on slopes steeper than <br />3H:1V, horizontal benches shall be excavated into the slope to allow fill to be placed in <br />horizontal lifts. The CONTRACTOR shall continuously bench and key embankment material <br />into the existing material a minimum of 2 feet. <br />E. The CONTRACTOR will be responsible for the safety of temporary construction slopes. <br />CONTRACTOR shall inspect all temporary and permanent open-cut excavations on a regulaz <br />basis for signs of instability. Should signs of instability be noted, CONTRACTOR shall <br />immediately undertake remedial measwes and shall notify MANAGER immediately. <br />Permanent cut slopes shall be left in smooth, safe, and stable condition at the end of the workday. <br />F. CONTRACTOR shall final grade excavations within the valley leach facility to establish . <br />positive drainage to the Pregnant Solution Storage Area. In no case will depressions or bowls be <br />permitted in the valley leach facility azea. <br />G. CONTRACTOR shall conduct all excavation and shoring operations in compliance with <br />applicable MSHA, Colorado State and Federal government laws and regulations. <br />• <br />3.05 SUBGRADE: <br />A. The MANAGER and CERTIFYING ENGINEER wIll inspect and approve the exposed <br />subgrade prior to any fill or Soil Liner being placed. CQA Monitor will confirni that the surface <br />of the subgrade is smooth and free of debris, grade stakes, angulaz rocks, roots, branches, <br />vegetation, mud, ice, or frozen material If the subgrade is determined to be frozen, using the <br />criteria identified in Item 3.06.10 of Section 2200, the CONTRACTOR may either remove and <br />replace the frozen subgmde or wait until subsequent temperature monitoring indicates the fill is <br />unfrozen, at no cost to CC&V. The subgrade shall have no sudden sharp or abmpt changes in <br />grade. <br />B. CONTRACTOR is responsible for maintaining subgrades in a conditon satisfactory to <br />CERTIFYING ENGINEER. CONTRACTOR shall protect prepazed subgrades, including <br />previously approved subgrade, from weather, constmction equipment, or other factors as outlined <br />in Part 3.06 of the SPECIFICATIONS. Subgrade surfaces, including previously approved <br />subgrade, that become softened or otherwise unsuitable for placement of fill, shall be repaired to <br />CERTIFYING ENGINEER'S and MANAGER'S sa[isfacfion, at no cost to CC& V. <br />C. Prior to placement of fill materials, CONTRACTOR shall scarify all in-situ materials to a depth <br />of 6-inches, moisture condition, and recompact the subgrade. Compactive effort shall be <br />adequate to obtain a minimum of 95 percent of maximum dry density as determined by the <br />standazd Proctor test (ASTM D698) for the particulaz fill material. Moisture conditioning shall <br />be adequate to achieve a uniform moistwe and density. Tn rock azeas, the CONTRACTOR <br />shall prepaze the subgrade by removing loose rock fragments until competent foundaton material <br />is encountered as approved by CERTIFYING ENGINEER. <br />I • <br />D. If the underlying material is unsuitable to permit proper compaction of the subgrade, <br />CONTRACTOR shall loosen, aerate (or excavate and remove), and recompact the subgrade <br />until the top layer can be compacted as required. The recompacted surface shall then be <br />scarified, as needed, to provide a good bond between the foundation and fill materials. <br />Section 02200 Page 6 of 17 Mazch 22, 2000 <br />Earthworks Golder Associates Revision 7 <br />J.W9JOB5~043311pLLVC CERrb]CATfON REPOR'NHASE IVC OSA CERIWPPENDICiESAPPENDIX E rECkEJICAL SPECIFICATfoNS`U2200R] DOC <br />