Laserfiche WebLink
4. Leak Detection Fill -material approved by MANAGER and CERTIFYING <br />ENGINEER conforming to the following SPECIFICATION: <br />u <br />Plasticity lndex: 0 <br />• <br />5. Low Volume Solution Collection Fill and Bedding Fill -material approved by <br />MANAGER and CERTIFYING ENGINEER conforming to the following <br />SPECIFICATION: <br />v. U.S. Standard ^', ; ' ' Peiceut Passing ?, :: <br />"Sieve Size ~ ° ~ ~ by D We' hf • • _ <br />I-inch 100 <br />3/8-inch 40 - 70 <br />No. 4 5 - 55 <br />No. 200 0 -10 <br />Plasticity Index: 0 <br />6. Soil Liner Fill -processed materials as approved by MANAGER and CERTIFYING <br />ENGINEER, conforming to the following SPECIFICATION: <br />U.S. Standard <br />~.:~Sieve3ize -- „ Percent Passiag , <br />6y Dry Wei hf <br />2 inch 100 <br />No. 200 15 - 50 <br />Plasticity Index: 10 minimum <br />Hydraulic Conductivity 1x10' cm/sec maximum <br />I• <br />7. Drain Cover Fill - material approved by MANAGER and CERTIFYING <br />ENGIlVEER confomring to the following SPECIFICATIONS: <br />- ihS. Standacd - Percent Passim <br />Sieve Size' " ti 'D Wei "tit' <br />I-1/2-inch 100 <br />3/4-inch 70 - 100 <br />No.4 5-50 <br />No. 200 0 - 8 <br />Plasticity Index: 0 <br />Section 02200 Page 3 of 17 Mazch 22, 2000 <br />Earthworks Golder Associates Revision 7 <br />1:~A410BSW13-21 ]OWC CER'I'IFICA'riON REPOATPHASE NC OSA CEB'MPPENDrC~SWPPENOIX E rECHMCAL SPECQ~"ICATIONSU122WR]Ix1C <br />