Laserfiche WebLink
OVENT VAULT <br />PLAN VIEW <br />SCALE: 1/2"=V-0" <br />COVER END OF PIPE W/ <br />CORROSION RESISTANT 1/2" <br />MESH BIRD SCREEN <br />6' -0" <br />6" 1800 RETURN BEND 109 <br />- 6" SCH 40 STEEL PIPE 108 <br />LADDER RUNGS <br />(OPPOSITE SIDE)I <br />HEAT TAPE <br />(21005) <br />403 <br />LID WITH 30 "x 30" <br />HATCH <br />110 VAC <br />OUTLET <br />(2005) <br />r/ r <br />60 "x 4' HIGH MANHOLE \ ^ <br />400 BARREL SECTION <br />GRADE BEAM <br />NOTE: LADDER RUNGS <br />NOT SHOWN. <br />(VENT VAULT <br />SECTION A -A <br />SCALE: 1 /2 " =1' -0" <br />COVER END OF PIPE W/ <br />CORROSION RESISTANT <br />1/2" MESH BIRD SCREEN <br />11-111- <br />HOLD <br />3,_0., <br />�\X\ <br />� \X 6 "SCH 40 <br />\ <br />\ \\\ / \\ STEEL PIPE <br />\ i FIELD VERIFY <br />DIMENSIONS <br />107 6" 90 <br />ELBOW <br />7" DIA. CASTOUT GRADE BEAM / / / <br />SEAL W/ MASTIC \/j /j\ 6" 150# FLANGE <br />� 116 <br />LW <br />6' 0 <br />(Rik f r • , , ," <br />fw , .. <br />0 <br />r` <br />26" SDR 17 + <br />121 FLANGE ADAPTER r` <br />AND RING Q 6" GRAVEL BASE 700 <br />COMPACTED <br />FLOW ► <br />26 "x 6" SiDR 17 REDUCING TEE 115 <br />(TRIM BRANCH OUTLET TO LENGTH) <br />OVENT VAULT DISCHARGE VENT <br />SECTION B -B (�)ELEVATION <br />SCALE: 1/2"=V-0" SCALE: 1/2"=V-0" <br />NO. DATE MADE BY CKD. BY REMARKS "This drawing together with any and alll additions, REV. NO. 1 2 3 4 5 a 7 a 9 DRAWING NO. DRAWING NO. REFERENCE <br />ISSUED <br />10/31/01 DCM SIAM APPROVED FOR CONSTRUCTION corrections, changes and alterations thlereof Is the ¢ ' 5 -2 -1014 DISCHARGE PIPELINE PLAN AND PROFILE <br />= Qj 8/03 DCM SMM 2003 PROJECT REVISIONS property of Climax Molybdenum Compomy and IS D 5 -2 -1018 DISCHARGE PIPELINE PLAN AND PROFILE <br />furnished on the express condition thatt it shall W w <br />W 0 not be reproduced, copied, lent, or disfposed of ¢ = 5 -7 -ton VENT VAULT ELECTRICAL <br />Q directly or indlrecily, nor used for any other I-- <br />yt <br />L purpose than for which it is specificallyy furnished Z W <br />Q without the prior written consent of smid Climax d LL <br />Molybdenum Company." <br />LIGHT FIXTURE ON <br />POLE TO INDICATE <br />POWER ON <br />(2005) <br />401 <br />60 "X2' MANHOLE <br />SECTION <br />(FIELD VERIFY) <br />11, 1 / �- GROUND SURFACE <br />^ <br />/jai\ <br />6" AIR VALVE 305 <br />6" BF VALVE 306 <br />6" SDR 17 FLANGE ADAPTER 122 <br />Z"-- 6" RETURN BEND 109 <br />6" FLANGE (2 EA.) 116 <br />6" BF VALVE 306 <br />4' -0" <br />L-- <br />26 "X6" SDR 26 117 <br />REDUCING TEE \ <br />GROUND <br />SURFACE <br />26" SDR 26 TEE 139 <br />26" SDR 26 HDPE FLANGE 120 <br />ADAPTER AND RING <br />Henderson Millwater Barge System <br />Discharge Pipeline <br />Vent Vault and Discharge Vent <br />Plan and Sections <br />TO FLOOD BYPASS VAULT <br />Specialist: ACS <br />Permit #: M1977342 Confidential ?: NO <br />Class: Revision Type /Seq.: TR -014 <br />From: Henderson To: DMG <br />Doc. Name: Barge System, 2004 Construction Drawing, <br />Discharge Pipeline, Vent Vault <br />Date: Z/ 12 /2004 <br />W. W. Wheeler and Associates, Inc. wMew, D". No. <br />—i Water Resource Engineers 11333.15c -41 <br />;Ilmax Molybdenum Henderson MITI <br />Prarahan, Colorado <br />MADE BY SCALE <br />DCM 1/23/01 112" = 1' -0" <br />ACCEPTED BY DRAWING NO. <br />CHECKED S M M Y 8 /1 /01 1 5 -e -1003 <br />