My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1992-09-01_REVISION - M1988112
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1988112
>
1992-09-01_REVISION - M1988112
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2021 5:17:51 AM
Creation date
11/21/2007 10:49:25 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1988112
IBM Index Class Name
Revision
Doc Date
9/1/1992
Doc Name
QUALITY ASSURANCE/QUALITY CONTROL-PROTOCOLS FOR THE COLLECTION OF SURFACE AND GROUND WATER
Type & Sequence
TR6
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
166
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
~ ~l~l~, <br />western Auae CORE LABORATORIES <br />InterPational <br />* 1 T 1 F <br />ANALYTICAL CHEMISTRY DIVISION QUALITY ASSURANCE MANUAL <br />' SOP N0. REV1510N ND. EFFECTIVE DATE PAGH <br />HC-QAC-02 0 1!06!92 80 of 104 <br />' <br /> when sample extractions for semivolatiles, pesticides or herbicides are <br /> performed. <br />' <br /> Extraction Blanks <br />' Extraction blanks must be analyzed every time samples are extracted. This <br /> extraction blank must be the same matrix type as the samples being <br />' processed. Purified silica sand may be used as an extraction material for <br />soil/sludge matrices <br /> . <br />' InitiallContinuing Calibration Verification <br /> An initial calibration must be performed every time that a GC column is <br /> replaced, the mass spectrometer source is cleaned or repaired, or any time <br />' major modifications are made to the instrument system. Daily calibrations are <br /> required to verify proper equipment operation prior to sample analysis. If the <br />' daily calibration verification does not meet method-specified acceptance <br /> criteria, a new initial calibration must be performed. Acceptance criteria for <br /> intial and continuing calibration verifications are provided in the applicable <br />' analytical method. <br /> Svstem Performance Standard <br /> <br /> GC/MS system performance check standards ituning compounds) must be <br /> analyzed daily for volatile and semivolatile analyses. <br /> <br /> Surrogate Recoveries <br />' Surrogates are required for volatile, semivolatile, pesticide, and herbicide <br /> analyses. <br /> Surrogate recoveries must meet the method-specified QC limits. When <br /> surrogate recoveries do not meet the method-specified criteria, that sample <br /> must be reanalyzed. If surrogate recoveries on the reanalysis still do not meet <br />' method-specified limits, a probable matrix interference problem exists, and the <br /> sample data should be qualified as estimated. Do not report these results <br /> until the data has been reviewed and approved by the laboratory section <br /> supervisor or the QA/QC coordinator. <br />1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.