11 <br />SECTION 2: PROTOCOL FOR WATER SAMPLE HANDLING AND <br />' GROUND WATER SAMPLE COLLECTION <br />2.1 Water Sample Handling and Management <br />Water sample handling and management will be conducted in <br />accordance with the following procedures. <br />' 2.1.1 Receive Sample Containers. Laboratory Water and Coolers fron~Labor~tor <br />' These items, when received, will be checked by the field sampling <br />personnel to verify that they are in compliance with project <br />specifications. Empty sample containers and laboratory water will <br />' be received in coolers. A chain-of-custody form will be received <br />with the above-mentioned items. Laboratory de-ionized water <br />' provided with the sample bottles, and the sample containers, will <br />be enumerated on the chain of custody. After these items have been <br />' checked and found to be in compliance they will be replaced into <br />the cooler. <br />' 2.1.2 Collect Samples and Record Field Data: samples will be collected in <br />accordance with site-specific protocols as defined in Sections 2.2, <br />3.2 and 4.2. Field data will be recorded at the time of sample <br />collection on the Field Data Collection Sheet (Appendix B). <br />Immediately after a sample is collected, sample identification will <br />be recorded on the sample container (and on the Field Data <br />' Collection Sheet) and this container will then be placed in an iced <br />cooler. If, at any point, there is a deviation frdm sample <br />' collection protocols as outlined in the above-referenced sections, <br />these deviations must be noted on the chain of custody and in the <br />' field book. <br /> <br /> -~- <br /> <br />