Fields
Template:
DRMS Permit Index
Permit No
M1998013
IBM Index Class Name
Revision
Doc Date
1/21/2003
Doc Name
DRAFT Slurry Wall Construction Specifications
From
Tetra Tech
To
DMG
Type & Sequence
AM1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
B. Undergound Utilities <br />.Known utilities and structwes adjacent to or encountered in the work are shown <br />on the Drawings. The locations shown aze taken from existing records and the <br />best information available from existing utility plans, however, it is expected that <br />there may be some discrepancies and omissions in the locations and quantities of <br />utilities and structures shown. Those shown are for the convenience of the <br />Contractor only, and no responsibility is assumed by the Engineer for their <br />accwacy or completeness. <br />PART 3 -CONTRACTOR'S RESPONSIBILITY FOR UTILITY PROPERTIES AND SERVICE <br />3.01 GENERAL <br />A. Where the Contractor's operations could cause damage or inconvenience to railway, <br />telegraph, telephone, television, oil, gas, electricity, water, sewer, or imgation systems, <br />the operations shall be suspended unfil all arrangements necessary for the protection of <br />these utilities and services have been made by the Contractor. <br />B. Notify all utility offices which are affected by the construction operation at least 48 hours <br />in advance. Under no circumstances expose any utility without first obtaining permission <br />from the appropriate agency. Once permission has been ganted, locate, expose, and <br />provide temporary support for all existing underground utilities. <br />C. The Contractor shall protect all utility poles from damage. If interfering power poles, <br />telephone poles, guy wires, or anchors aze encountered, notify the Engineer and the <br />appropriate utility company at ]east 48 hours in advance of construction operations to <br />permit the necessary arrangements for protection or relocation of the interfering stmcture. <br />D. The Contractor shall be solely and directly responsible to the Owner and operators of <br />such properties for any damage, injury, expense, loss, inconvenience, delay, suits, <br />actions, or claims of any character brought because of any injuries or damage which may <br />result from the construction operations under this Contract. <br />E. The Engineer shall not be responsible to the Contractor for damages as a result of the <br />Contractor's failwe to protect utilities encountered in the work. <br />F. If the Contractor while performing the Contract discovers utility facilities not identified <br />in the Drawings or Specifications, he shall immediately notify the utility, and the <br />Engineer in writing. <br />G. Tn the event of interruption to domestic water, sewer, storm drain, or other utility services <br />as a result of accidental breakage due to construction operations, promptly notify the <br />proper authority- Cooperate with said authority in the restoration of service as promptly <br />as possible and bear all costs of repair. In no case shall interruption of any water or <br />utility service be allowed to exist outside working hows unless prior approval is ganted. <br />H. The Contractor shall replace, at his own expense, any and all other existing utilities or <br />structures removed or damaged during construction, unless otherwise provided for in <br />these Contract Documents or ordered by the Engineer. <br />Draft -Technical Specifications <br />01/99 Section 01160 -Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.