My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1992-11-01_REVISION - M1988112
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1988112
>
1992-11-01_REVISION - M1988112
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2021 6:22:23 AM
Creation date
11/21/2007 9:02:06 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1988112
IBM Index Class Name
Revision
Doc Date
11/1/1992
Doc Name
QUALITY ASSURANCE QUALITY CONTROL PROTOCOLS FOR THE COLLECTION OF SURFACE & GROUND WATER QUALITY DA
Type & Sequence
TR6
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
169
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CORE LABORATORIES <br />'®~~~ <br />Western Atlas <br />International <br />..~,r,..~ cam.. <br />' TITLE <br />ANALYTICAL CHEMISTRY DIVISION QUALITY ASSURANCE MANUAL <br />' SOP NO. REVISION N0. EFFECTIVE DATE PAGE <br />HC-QAC-02 0 1 /06/92 76 of 104 <br />' <br /> Reference/LCS standards should be analyzed once per batch of samples, <br />' where available. <br /> The analyzed recovery value must be within 90-110% of the known value. <br /> When available, the recovery limits which are specified by the source of the <br />' reference standard (EPA, NBS, etc.) should be used. <br /> The following quality control guidelines apply to the majority of general <br />' inorganic analyses which are performed on-site. <br />' pH(Alkaf+nitv(Acidity <br /> • pH meters must be calibrated daily or at each use. <br />' <br /> • Calibration verification using two buffer solutions at a pH of 4, 7, or 10 <br /> must be performed prior to sample analysis. <br /> <br /> • A method blank and reference standard (if available) must be analyzed with <br /> each sample batch. <br /> <br /> • Laboratory duplicates must be analyzed once per batch or at a frequency <br /> of 10% of the sample population, whichever is greater. <br />' <br /> Matrix spikes are not required. <br />' Gravimetric Parameters <br />' An analytical balance with a resolution of 0.0001 grams should be used for <br />the majority of gravimetric parameters. Top-loading balancgs may be used <br /> for certain parameters, such as percent moisture. <br />' Drying ovens used for gravimetric analysis must be monitored for correct <br /> temperature adjustments on a daily basis (see section 9.21. <br />' A method blank and reference standard or stock standard (if available) must. <br /> be analyzed with each sample batch. <br /> • Laboratory duplicates must be analyzed once per batch or at a frequency <br />I of 10°!° of the sample population, whichever is greater. <br />I <br />
The URL can be used to link to this page
Your browser does not support the video tag.