<br /> <br />' Immediately after collection, all samples must be placed in iced <br />coolers. The sample bottles required for each sample site are <br />listed in Table 5 (metals, cyanide). Sample preservation, pre- <br />, treatment and holding times, as outlined in Table 5, will be <br />strictly adhered to. <br />' 4.2.7 Sample Filtration: Process samples requiring on-site filtration <br />will be filtered through a 0.45-micron filter. <br />' Samples will be preserved directly following filtration. <br />' Filter apparatus will be cleaned by having the solutions "pulled" <br />' through the apparatus prior to and after each use in the following <br />manner: <br />' (1) mild non-phosphatic detergent wash; <br />(2) tap water rinse; and <br />' (3) final rinse with de-ionized water. <br />' Following a filtration series of no more than 10 samples, a rinse <br />blank will be collected from the cleaned apparatus or, if <br />' applicable, through an un-used filter cartridge, by running <br />laboratory-provided de-ionized, distilled water throughout the <br />entire filtering apparatus. Analysis of this rinse blank will be <br />' used to validate cleaning procedures. <br />' 4.3 Record Keeping <br />' All field data will be recorded in the Field Data Collection <br />Sheets. These data will include: weather conditions, volume of <br /> water removed from the lysimeter, lysimeter designation or <br /> location, the sequence in which the samples were t8ken, the <br /> sampler's name and the condition of the lysimeter. A Field Data <br /> Collection Checklist will also be filled out for each sample site <br /> <br />-32- <br />`J <br />