Laserfiche WebLink
o Amount of Material Finer than the No. 200 Sieve (once daily) <br />o Slump (twice daily) <br />o Density (twice daily) <br />o Permeability (with moisture content) -once every 15001inear feet. Total of 5 <br />tests for the project. <br />Tests shall conform to the following standards specified below: <br />• Viscosity and Mud Density of Bentonite Slurry -API RP 13B <br />Percent Finer than No. 200 Standard Sieve - ASTM D 1140 <br />^ Moisture Content - ASTM D 2216 <br />^ Slump - ASTM C 143 <br />Unit Weight of Soil-Bentonite Backfill - ASTM D 6023 <br />^ Permeability - ASTM D 5084 <br />Whenever tests indicate material or workmanship not in accordance with the specifications, <br />work shall be halted and the cause of the discrepancy shall be identified. Work not in <br />accordance with the specifications shall be removed, replaced, repaired, or otherwise corrected <br />so as to conform to the specifications. <br />G:\PROJEC7S\IO]021-000 COVelaod Ready Mix Shirty Wall~R. Records and CortespondenceR.ll R~pons~Final$Wrty Wall Dcsiyu Repartdoc 11 <br />