Laserfiche WebLink
<br />2 Boxes Specified For Generation Of Central Block Base <br />Length Of Line Segments For Active And Passive Portions Of <br />Sliding Block Is 20.0 <br />Box X-Left Y-Left X-Right Y-Right Height <br />No. (ft) (ft) (ft) (ft) (ft) <br />1 79.50 29.00 80.50 29.00 1.00 <br />2 464.50 164.00 465.50 164.00 1.00 <br />1 <br />Following Are Displayed The Ten Most Critical Of The Trial <br />Failure Surfaces Examined. They Are Ordered - Most Critical <br />First. <br />* * Safety Factors Are Calculated By The Modified Tanbu Method * <br />Failure Surface Specified By $ Coordinate Points <br />Point X-Surf Y-Surf <br />No. (ft) (ft) <br />1 78.55 30.00 <br />2 79.73 28.88 <br />3 464.81 164.43 <br />4 478.68 178.83 <br />5 483.73 198.19 <br />6 442.30 216.25 <br />7 494.27 236.17 <br />8 497.82 248.00 <br />*** 1.640 *** <br />Failure Surface Specified By 9 Coordinate Points <br />Point X-Surf <br />No. (ft) <br />1 77.OII <br />2 79.68 <br />3 464.65 <br />4 478.77 <br />5 491.56 <br />6 494.76 <br />7 501.48 <br />8 515.16 <br />9 516.37 <br />*** 1.641 <br />*** <br />Y-Surf <br />(ft) <br />30.00 <br />28.63 <br />164.07 <br />178.24 <br />193.61 <br />213.36 <br />232.19 <br />246.78 <br />248.00 <br />