Laserfiche WebLink
--Version:-- 18siwa11-3.-1-030--- -- ~ ~ - --- -- ~-- - - - -Prepared By: - -BURNEIT CONSULTING <br />ENGINEERS, LTD. <br />Project Name: North Eagleview Drainage Channel Contact: TOM BURNETT <br />Site: #3 to F St Phone: (970)723-006t <br />Safety Factor Summary: <br />Lowest Values for the Project <br />Type of Wall Gravity Wall <br />Panel Layer/ Failure Vaziable Standard Calculated Acceptable? <br />Course Mode Name Requiremem Value <br />*** No Gravity Panels *** <br />Type of Wall Geogrid Reinforced Wall <br />Panel Layer/ Failure Variable Standard Calculated Acceptable? <br />Course Mode Name Requirement Value <br /> External <br />2 Base Sliding FSsI 1.5 3.428 OK <br />2 Overturning FSot 2.0 6.507 OK <br />2 Bearing Capacity FSbc 2.0 30.593 OK <br /> Internal <br />33 2 Pullout FSpo(2) 1.5 1.684 OK <br />3 1 Tensile Overstress FSot(1) 1.0 2.196 OK <br />2 1 Sliding FSsI(1) 1.5 6.449 OK <br />3 I Connection FScs(1) LS 2.618 OK <br />2 2 Bulging FSsc(2) I.5 16.126 OK <br />1 Umeinforced Height FSot 1.5 3.765 OK <br />All Failures for Each Pauel <br />Panel Wall Layer/ Failure Variable Standard Calculated <br />Type Course Mode Name Requirement Value <br />*** 34 Panels Analyzed. *** <br />*** All Analyzed Panels Met Minimum Design Standards Requirements *** <br />12:55 P~ Page 11 <br />