Laserfiche WebLink
Geotechnical Engineering Report <br />Eagleview Drainage Channel <br />Southwest of "F" Street and 35ei Avenue <br />Terracon Project No. 21035051 <br />Terracon <br />The soils to be penetrated by the proposed excavations may vary significantly across the site. The <br />preliminary soil classifications are based solely on the materials encountered in widely spaced <br />exploratory test borings. The contractor should verify that similar conditions exist throughout the <br />proposed area of excavation. If different subsurface conditions are encountered at the time of <br />construction, the actual conditions should be evaluated to determine any excavation modifications <br />necessary to maintain safe conditions. <br />As a safety measure, it is recommended that all vehicles and soil piles be kept to a minimum lateral <br />distance from the crest of the slope equal to no less than the slope height. The exposed slope face <br />should be protected against the elements. <br />GENERAL COMMENTS <br />Terracon should be retained to review the final design plans and specifications so comments can be <br />made regarding interpretation and implementation of our geotechnical recommendations in the <br />design and specifications. Terracon also should be retained to provide testing and observation <br />during excavation, grading, foundation and construction phases of the project. <br />The analysis and recommendations presented in this report are based upon the data obtained from <br />the borings performed at the indicated locations and from other information discussed in this report. <br />This report does not reflect variations that may occur between borings, across the site, or due to the <br />modifying effects of weather. The nature and extent of such variations may not become evident <br />until during or after construction. If variations appear, we should be immediately notified so that <br />further evaluation and supplemental recommendations can be provided. <br />The scope of services for this project does not include either specifically or by implication any <br />environmental or biological (e.g., mold, fungi, bacteria) assessment of the site or identification or <br />prevention of pollutants, hazardous materials or conditions. If the owner is concerned about the <br />potential for such contamination or pollution, other studies should be undertaken. <br />This report has been prepared for the exclusive use of our client for specific application to the <br />project discussed and has been prepared in accordance with generally accepted geotechnical <br />engineering practices. No warranties, either express or implied, are intended or made. Site safety, <br />excavation support, and dewatering requirements are the responsibility of others. In the event that <br />changes in the nature, design, or location of the project as outlined in this report are planned, the <br />conclusions and recommendations contained in this report shall not be considered valid unless <br />Terracon reviews the changes and either verifies or modifies the conclusions of this report in writing. <br />8 <br />