My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000-01-28_REVISION - M1977208 (3)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1977208
>
2000-01-28_REVISION - M1977208 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2021 5:56:49 PM
Creation date
11/21/2007 1:17:05 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977208
IBM Index Class Name
Revision
Doc Date
1/28/2000
Doc Name
RESPONSE TO TECHNICAL ADEQUACY REVIEW OF TR 001 LYONS QUARRY PN M-77-208 SOUTHDOWN INC
From
BANKS AND GESSO LLC
To
DMG
Type & Sequence
TR1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />5.0 REAGENTS <br />5.1 See Section 5.0 of Method 7000. <br />5.2 Preparation of standards: <br /> <br />5.2.1 Stock solution: Dissolve 1.303 g thallium nitrate, T1N03 <br />(analytical reagent grade), in Type II water, acidify with 10 mL <br />concentrated HNO~, and dilute to 1 liter with Type I[ water. Alterna- <br />tively, procure a certified standard from a supplier and verify by <br />comparison with a second standard. <br />5.2.2 Prepare dilutions of the stock solution to be used as <br />calibration standards at the time of analysis. The calibration standards <br />should be prepared using the same type of acid and at the same <br />concentrations as in the sample after processing (0.5% v/v HNO,). <br />5.3 Palladium chloride: Weigh 0.25 g of PdClz to the nearest 0.0001 g. <br />Dissolve in 10 mL of 1:1 HNO, and dilute to 1 liter with Type II water. Use <br />equal volumes of sample and palladium solution. <br />6.0 SAMPLE COLLECTION. PRESERVATION. AND HANDLING <br />6.1 See Chapter Three, Section 3.1.3, Sample Handling and Preservation. <br />7.0 PROCEDURE <br />7.1 Sample preparation: The procedures for preparation of the sample are <br />given in Chapter Three, Section 3.2. <br />7.2 See Method 7000, Paragraph 7.3, Furnace Procedure. The calculation <br />is given in Method 7000. Paragraph 7.4. <br />8.0 QUALITY CONTROL <br />8.1 See Section 8.0 of Method 7000. <br />9.0 METHOD PERFORMANCE <br />9.1 Precision and accuracy data are not available at this time. <br />9.2 The performance characteristics for an aqueous sample free of <br />interferences are: <br />Optimum concentration range: 5-100 ug/L. <br />Detection limit: 1 ug/L. <br />7841 - 2 <br />CO-ROM Revision 0 <br />Date September 1986 <br />