Laserfiche WebLink
Applegate <br />Group, ~~~. <br />Maz¢h 11, 2005 <br />Ms: Suzanne,Jaozen - <br />Lafarge West, Inc. . <br />10170 Church Ranch Way, Suite 200 <br />Westminster, CO 80021 <br />RE: Lafarge West, Inc.,,Riverbend Operation , <br />Response to Adequacy Review <br />112c Permit Amendment Ol, Permit No..M-2000-016 <br />Deaz Suzanne: <br />- The purpose of this letter is to 'provide you with responses to The Division' of.Minerals and <br />Geology's ("DMG") adequacy 7eview of the 112c Permit Amendment to Lafarge West, Inc.. <br />("Lafarge's") Riverbend Operation- (Permit No: M-20,00=016). Specifically, `this letter will <br />address unresolved issues from DMG's comments regazding Exhibits D, E and G in its adequacy- <br />- review letter dated February 11; 2005. For clatity we will .list each of DMG's comments <br />;followed by the respective responses.: ` <br />9. The Reclamation Plan identifies five -cells and one existing pond that will be used for silt <br />storage and reclaimed as wetlands: Since these silt storage cells. have the potential. to act <br />as barriers to groundwater flow, the. applicant-must assess the potential impact mid <br />commit to speck mifigatiori measures: <br />The silt ponds identified in the reclamation plan will impact the flow. of groundwater surrounding ; <br />each pond by effectively lowering the hydraulic conductivity in the area:- Similar to the effects <br />on the groundwater flow in the vicinity of a lined pond, some increase in groundwater elevation, ,. <br />or mounding may occur on the up-gradient: side of each silt pond;.decreases in the elevation of <br />the groundwater table, .or shadowing,. may occur on the down-gradient side of each silt. pond. <br />Based on our review of the location wells:and other potentially effected structures in the vicinity <br />of the silt ponds, as well as our review. of the groundwater modeling previously completed for , <br />the site, the effects on the groundwater flow.from these, silt ponds is negligible. There are five <br />silt ponds identified in the reclamatiomplan: Each of these ponds will. be reclaimed as wetlands,. <br />and we will discuss the potental impacts from each in turn. <br />First, Ce112 in Phase 1 will be located on the east side of the South Platte River in the southeast . <br />corner ofthe site: There aze two wells located to the north and southeast from this pond-that <br />could potentially be impacted by this pond. Lafarge controls the well located to the north.of the <br />• .pond, permit no: 13699; as such we will not consider the effects to this well. As;for the potential <br />. effects. to the well located to the southeast of the pond (permit no.' 163521), the lining of Cell. 1; .. - <br />,which lies. between Cell 2 and the well, will have. a greater impact on the water levels in the well. <br />- The groundwater model determined the ultimate effecYo£the reclamation of the site on the well <br />~- ~ 1499.West120ffi Avenue, Suite 200 ~ - ~, ~ - - -. .~ (303)452-6611 ~•Fax(303)452-2759- •,' <br />Denver, Colorado 80234-2759 www.applegategraup.com <br />