Laserfiche WebLink
<br />1 130.0 135.0 447.0 19.0 .00 .0 1 <br />2' 130.0 135.0 2000.0 .0 .00 .0 1 <br />1 <br />A Critical Failure Surface Searching Method, Using A Random <br />Technique For Generating Circular Surfaces, Has Been Specified. <br />20 Trial Surfaces Have Been Generated. <br />l0 Surfaces Initiate From Each Of 2 Points Equally Spaced <br />Along The Ground Surface Between X = 150.00 ft. <br />and X = 250.00 ft. <br />Each Surface Terminates Between X = 300.00 ft. <br />and X = 400.00 ft. <br />Unless Further Limitations Were Imposed, The Minimum Elevation <br />At Which A Surface Extends Is Y = 12.00 ft. <br />10.00 ft. Line Segments Define Each Trial Failure Surface. <br />1 <br />Following Are Displayed The Ten Most Critical Of The Trial <br />Failure Surfaces Examined. They Are Ordered - Most Critical <br />First. <br />* * Safety Factors Are Calculated By The Modified Bishop Method <br />Failure Surface Specified By 30 Coordinate Points <br />Point X-Surf Y-Surf <br />No. (ft) (ft) <br />1 150.00 115.98 <br />2 159.57 113.07 <br />3 169.27 110.66 <br />4 179.09 108.73 <br />5 188.98 107.31 <br />6 198.94 106.38 <br />7 208.93 105.96 <br />8 218.93 106.04 <br />9 228.92 106.63 <br />10 238.86 107.71 <br />11 248.73 109.30 <br />12 258.51 111.39 <br />13 268.17 113.96 <br />14 277.69 117.02 <br />15 287.05 120.55 <br />